OCCUPATIONAL SAFETY AND HEALTH
Instructions for labor protection when working with the drying chamber. Full document Occupational Safety and Health / Standard instructions for labor protection Safe Operation 1. General requirements for labor protection 1.1. This instruction has been developed on the basis of regulations on labor protection. 1.2. Persons at least 18 years of age who are specially trained and have passed the knowledge test of EEEE, PTE, occupational safety instructions, etc. are allowed to operate and maintain the drying chamber. 1.3. Persons who are not related to this work are not allowed to perform work. 1.4. The drying chamber must be kept tidy and clean, both inside and around its structure. 1.5. If there is a power outage, turn off the circuit breaker that supplies power to the drying chamber. 1.6. Immediately notify the workshop management of noticed malfunctions in the drying chamber, and do not begin work without permission. 1.7. A sign must be posted on the drying chamber indicating the persons authorized to work with the drying chamber and the person responsible for safe operation. 1.8. Metal parts of the structure that may become live due to insulation damage must be grounded by connecting to the general grounding circuit of the workshop. 1.9. Before starting work, each employee must be instructed in the rules for the safe operation of electrical installations and strictly follow them. 1.10. Repair, adjustment and temperature control must be carried out by a specially trained person who is authorized to service and adjust the drying chamber and has safety group 3. 1.11. When the drying chamber is operating, it is strictly forbidden to climb onto its structure, open the cabinet door, or carry out any work on its adjustment and adjustment. 1.12. When repairing or inspecting the electrical equipment of the drying chamber, as well as when performing adjustment work, it is necessary to turn off the input machine. 2. Labor protection requirements before starting work 2.1. Before starting work, the employee must: 2.1.1. Make sure that the drying chamber is clean and free of foreign objects. 2.1.2. Check the trolley for transporting transformers for integrity and absence of transformer oil. 2.1.3. Check the seals of the doors, the integrity of the constipation of the drying chamber. 2.1.4. Make sure there is a removable transport handle on the cart, install it on the cart and secure it. 2.1.5. Check the guides along which the trolley moves to ensure that there are no foreign objects in the path of movement, 2.1.6. Loading the cart in the drying chamber must be carried out by 2 people who are specially trained, have slinger certificates and are authorized to perform stropping work. 2.1.7. When loading and unloading the trolley, the following must be observed: correct slinging of the transformer, in accordance with the slinging diagram for the active part of the transformer, depending on the type of transformer, correct installation of the transformer on the trolley. 2.1.8. When installing one active part on a trolley, the transformer is installed in the center of the trolley along the direction of movement of the trolley. After which, the tension of the slings is relaxed and the stability of the active part is checked. Then the active part is secured with stretch marks. 2.1.9. When installing several active parts of transformers on a trolley, special attention should be paid to the weight of all transformers and the uniform distribution of the load on the trolley relative to the center. Transformers must be located along the direction of movement of the trolley. 2.1.10. The distance between transformers on the cart should be as minimal as the design of each transformer can allow, and the number of transformers installed is determined by the dimensions of the cart. Transformers must not extend beyond the edge of the trolley. The axles on the trolley are spaced apart for a more stable position of the trolley to prevent it from tipping over when the trolley moves. 3. Labor protection requirements during work 3.1. Before rolling out (rolling) the cart into the drying chamber, the worker responsible for repairing the transformer located in the drying chamber must receive an order from the foreman, which must indicate the number and names of persons who will transport the cart. 3.2. Before transportation, the worker responsible for repairing the transformer must make sure that the rail tracks of the drying chamber are intact and that there are no foreign objects on them, after which, by gently pressing the transport handle of the trolley, the trolley is rolled into (out of) the drying chamber. Then close the door to the drying chamber tightly. 3.3. After starting the drying chamber, the worker responsible for drying transformers monitors the temperature conditions of the drying chamber and the uninterrupted drying process throughout the entire process. 3.4. During the operation of the drying chamber it is strictly prohibited: 3.4.1. Open doors. Open the chamber doors only when the chamber temperature drops to 70°C. 3.4.2. Carry out hot work near the drying chamber. 3.4.3. Change its temperature. 4. Labor protection requirements at the end of work 4.1. Turn off the dryer. 4.2. Remove debris from the drying chamber, remove oil from the trolley. 4.3. Upon completion of work, roll the empty cart into the drying chamber and lock the doors. 4.4. Report to the master when the work is completed. Take off your overalls, put them in a special place, wash your hands and face with warm water and soap, or take a shower. 5. Labor protection requirements in emergency situations 5.1. In emergency mode, turn off the power supply to the drying chamber control cabinet. 5.2. Report to the master about the observed malfunctions. 5.3. In case of injury or illness, stop work, notify the foreman, go to the first aid station or call an ambulance. 5.4. In case of electric shock, it is necessary to immediately release the victim from the action of the current, observing the requirements of electrical safety, provide first aid and call a medical officer, notify the management. 5.5. In the event of a fire, inform the fire brigade by phone _______, management and start extinguishing. We recommend interesting articles Section Standard instructions for labor protection: ▪ Cutaway transporter. Standard instruction on labor protection ▪ Hydraulic lift and telescopic tower operator. Standard instruction on labor protection ▪ Timber cargo loading and unloading. Standard instruction on labor protection See other articles Section Standard instructions for labor protection. Read and write useful comments on this article. Latest news of science and technology, new electronics: Artificial leather for touch emulation
15.04.2024 Petgugu Global cat litter
15.04.2024 The attractiveness of caring men
14.04.2024
Other interesting news: ▪ Plastic skin feels the force of touch ▪ Radeon RX 6900 XT NITRO+ graphics card ▪ Traces of early life in precious stones ▪ Digitization - the next level of grain and soy production News feed of science and technology, new electronics
Interesting materials of the Free Technical Library: ▪ section of the Antenna website. Article selection ▪ article by Om Georg. Biography of a scientist ▪ article Is it true that the conservatory is a shelter for homeless children? Detailed answer ▪ article Meadow cress. Legends, cultivation, methods of application ▪ article Wedge instead of a vice. Encyclopedia of radio electronics and electrical engineering
Leave your comment on this article: All languages of this page Home page | Library | Articles | Website map | Site Reviews www.diagram.com.ua |