Occupational safety instructions for an electrician for servicing electrical cables up to and above 1000 V. Full document

Occupational Safety and Health

Occupational Safety and Health / Standard instructions for labor protection

Comments on the article Comments on the article

Safe Operation

1. General requirements for labor protection

1.1. Persons at least 1000 years of age who have passed a medical examination, introductory briefing, briefing and on-the-job training, labor protection knowledge testing, internship and have a qualification group in electrical safety not lower than IV are allowed to work on servicing electrical cables up to and above 18 V.

1.2. The electrician for the maintenance of electrical cables is obliged to:

1.2.1. Know and comply with the rules on labor protection when working on cable lines, the scope of duties performed, annually confirm the qualification group for electrical safety;

1.2.2. Know the technology of work;

1.2.3. Know the procedure for checking and using manual mechanical and power tools, devices to ensure the safe production of work, protective equipment;

1.2.4. Perform only the work that is defined in the equipment operating instructions or job descriptions approved by the administration of the enterprise, and on condition that the safe ways of doing it are well known to him;

1.2.5. Know and be able to provide first aid to victims of accidents:

1.2.6. Comply with the rules of internal labor regulations;

1.2.7. Follow the instructions on fire safety measures.

1.3. When servicing electrical cables, the following hazardous and harmful production factors are possible:

  • dangerous voltage in the electrical circuit, the closure of which can occur through the human body, electric shock, electric arc burn;
  • work close to power lines;
  • insufficient illumination of the working area;
  • work with harmful substances (epoxy resins, antiseptics, insulating varnishes).

1.4. When performing work according to orders' and orders, organizational and technical measures must be carried out in full.

1.5. The victim or eyewitness immediately notifies the immediate supervisor of each accident at work.

1.6. For non-compliance with this instruction, the perpetrators are held accountable in accordance with the internal labor regulations or penalties determined by the Labor Code of the Russian Federation.

2. Labor protection requirements before starting work

2.1. Before starting work with electrical cables, check and make sure that the necessary tools, devices to ensure safe work performance, personal protective equipment, and fire extinguishing equipment are available and in good condition. The electrician's tool must be in the bag.

2.2. Put on special clothes, special shoes, corresponding to the nature of the proposed work, adjust them without allowing constraint when moving.

2.3. Inspect and prepare the workplace, put it in order, remove objects throwing work. Lay out the working tool and accessories, auxiliary material in a convenient and safe manner.

2.4. When working in an underground structure, natural or forced ventilation must be provided and an analysis taken for the oxygen content in the air, which must be at least 20%.

2.5. Collectors and tunnels equipped with forced ventilation, the latter must be turned on.

3. Labor protection requirements during work

3.1. Work only in serviceable and carefully fitted overalls and safety shoes, use personal protective equipment required at this workplace in accordance with current standards.

3.2. Work in underground cable structures, as well as inspection with a descent into them, must be carried out along with at least 3 people, of which two are insurers. Communication must be established between workers performing work and insurers. The foreman must have group IV.

3.3. In each section, it is necessary to have a list of gas hazardous underground structures approved by the head of the organization, with which operational personnel must be familiarized. All gas hazardous underground structures must be marked on the plan. Hatches and doors of gas hazardous premises must be securely locked and have signs in accordance with the state standard.

3.4. When working in sewers and tunnels, two hatches and two doors must be open so that workers are between them. A warning sign or a fence should be installed at the open hatch. Before starting work, team members should be familiar with the evacuation plan from the underground structure in case of unforeseen circumstances.

3.5. When opening wells, it is necessary to use a tool that does not produce sparks, and also to avoid hitting the cover on the hatch neck. A warning sign or a fence should be installed at the open hatch of the well.

3.6. It is allowed to stay and work in the well for one employee who has group 3, using a safety belt with a safety rope. The safety belt must have shoulder straps crossing at the back, with a ring at the intersection for attaching the rope. The other end should hold one with the belay workers.

3.7. When working in a well, it is not allowed to light blowtorches in them, install propane-butane cylinders, heat up compounds for pouring couplings and solder.

3.8. When carrying out hot work, shields made of refractory material should be used to limit the spread of flame and measures should be taken to prevent fire.

3.9. In collectors, tunnels in which cables are laid, when working with propane-butane, the total capacity of the cylinders in the room should not exceed 5 liters.

3.10. When burning cables, it is not allowed to be in the wells, and in tunnels and collectors it is allowed only from the areas between 2 open entrances. Do not work on cables while they are being burned.

3.10. It is not allowed to smoke in wells, sewers and tunnels, as well as at a distance of less than 5 m from open hatches.

3.11. During long-term work in wells, collectors and tunnels, the time spent in them must be determined by the worker issuing the order, depending on the conditions of the work.

3.12. In the event of the appearance of gas, work in wells, collectors and tunnels should be stopped, workers should be removed from the danger zone until the source of gas contamination is identified and eliminated.

3.13. To illuminate workplaces in wells and tunnels, 12 V lamps in explosion-proof design should be used.

3.14. At the workplace, the cable to be repaired should be determined:

  • when laying in a tunnel, collector, channel - by tracking, checking the layout with drawings and diagrams, checking by tags;
  • when laying cables in the ground - by checking their location with the laying drawings.

3.15. In all cases where there is no visible damage to the cable, a cable locator should be used.

3.16. When piercing the cable, you should use overalls, dielectric gloves and face and eye protection, while standing on an insulating base on top of the trench at the maximum distance from the pierced cable. The cable piercing must be carried out by two workers: the permitting or the manufacturer and the responsible work manager, one of them directly pierces the cable, and the second one supervises.

3.17. For grounding the piercing device, a ground electrode immersed in the soil to a depth of at least 0,5 m or cable armor can be used. Connect the grounding conductor to the armor by means of clamps, the armor under the clamp must be stripped.

4. Labor protection requirements in emergency situations

4.1. Each employee who discovers violations of the requirements of this instruction, labor protection rules or notices a malfunction of the equipment that poses a danger to people is obliged to report this to the immediate supervisor.

In cases where a malfunction of the equipment poses a threatening danger to people or the equipment itself, the employee who discovered it is obliged to take measures to terminate the operation of the equipment, and then notify his manager about this. Troubleshooting is carried out in compliance with safety requirements.

4.2. If an accident occurs during work, it is necessary to immediately provide first aid to the victim, report the incident to his immediate supervisor and take measures to preserve the situation of the accident, if this is not and is associated with a danger to life and health of people.

4.3. In case of electric shock, it is necessary to release the victim from the action of electric current as soon as possible, in case of work at height, take measures. preventing him from falling. The equipment should be disconnected using the plug-in connector switches, cut the supply wire with a tool with insulated handles. If it is impossible to turn off the equipment quickly enough, other measures must be taken to free the victim from the action of the current.

To separate the victim from current-carrying parts or wires, use a stick, board or some other dry object that does not conduct electricity; at the same time, the assisting person must stand on a dry, non-conductive place, or wear dielectric gloves.

4.4. In the event of a fire in a technical room, it is necessary to immediately start extinguishing it with the available means (carbon dioxide fire extinguishers, asbestos blankets, sand) and call the fire department.

4.5. In case of violation of the operating mode, damage or accident on the power-supplying equipment, the electrician must independently take measures to eliminate the malfunction and report the incident to the immediate supervisor or the person responsible for the electrical economy.

5. Labor protection requirements at the end of work

5.1. Make the necessary switch-offs. De-energize devices and equipment that are unnecessary for work.

5.2. If the repair work on the electrical equipment is completed, then it is necessary to remove the portable grounding, warning prohibition signs, about which to make an entry in the operational log.

5.3. Tidy up your workspace. Remove tools, accessories, overalls and protective equipment to the designated place.

5.4. Ensure the fire safety of the premises.

5.5. Wash face and hands thoroughly with warm water and soap.

 We recommend interesting articles Section Standard instructions for labor protection:

▪ Turner-revolver. Standard instruction on labor protection

▪ Work from the lift (tower). Standard instruction on labor protection

▪ Soldering gas soldering. Standard instruction on labor protection

See other articles Section Standard instructions for labor protection.

Read and write useful comments on this article.

<< Back

Latest news of science and technology, new electronics:

Artificial leather for touch emulation 15.04.2024

In a modern technology world where distance is becoming increasingly commonplace, maintaining connection and a sense of closeness is important. Recent developments in artificial skin by German scientists from Saarland University represent a new era in virtual interactions. German researchers from Saarland University have developed ultra-thin films that can transmit the sensation of touch over a distance. This cutting-edge technology provides new opportunities for virtual communication, especially for those who find themselves far from their loved ones. The ultra-thin films developed by the researchers, just 50 micrometers thick, can be integrated into textiles and worn like a second skin. These films act as sensors that recognize tactile signals from mom or dad, and as actuators that transmit these movements to the baby. Parents' touch to the fabric activates sensors that react to pressure and deform the ultra-thin film. This ... >>

Petgugu Global cat litter 15.04.2024

Taking care of pets can often be a challenge, especially when it comes to keeping your home clean. A new interesting solution from the Petgugu Global startup has been presented, which will make life easier for cat owners and help them keep their home perfectly clean and tidy. Startup Petgugu Global has unveiled a unique cat toilet that can automatically flush feces, keeping your home clean and fresh. This innovative device is equipped with various smart sensors that monitor your pet's toilet activity and activate to automatically clean after use. The device connects to the sewer system and ensures efficient waste removal without the need for intervention from the owner. Additionally, the toilet has a large flushable storage capacity, making it ideal for multi-cat households. The Petgugu cat litter bowl is designed for use with water-soluble litters and offers a range of additional ... >>

The attractiveness of caring men 14.04.2024

The stereotype that women prefer "bad boys" has long been widespread. However, recent research conducted by British scientists from Monash University offers a new perspective on this issue. They looked at how women responded to men's emotional responsibility and willingness to help others. The study's findings could change our understanding of what makes men attractive to women. A study conducted by scientists from Monash University leads to new findings about men's attractiveness to women. In the experiment, women were shown photographs of men with brief stories about their behavior in various situations, including their reaction to an encounter with a homeless person. Some of the men ignored the homeless man, while others helped him, such as buying him food. A study found that men who showed empathy and kindness were more attractive to women compared to men who showed empathy and kindness. ... >>

Random news from the Archive

UP Xtreme i11 Single Board Computer 11.08.2021

The UP Xtreme i11 single board computer will go on sale in September and is currently available for pre-order. The solution is based on the Intel Tiger Lake hardware platform.

The novelty is suitable for creating small form factor systems, such as nettops and IoT devices. The dimensions of the board are only 120 x 122 mm. Guaranteed compatibility with software platforms Windows 10, Yocto 3.1, Ubuntu 20.04.

Modifications are offered with various processors - from the dual-core Celeron 6305E chip to the quad-core Intel Core i7-1185GRE. All models support up to 64GB of DDR4-3200 RAM. SATA storage and M.2 2280 NVMe solid-state module can be connected.

The equipment includes 1Gb LAN and 2.5Gb LAN network controllers, and it is optionally possible to install Wi-Fi and Bluetooth wireless adapters, a 4G / LTE or 5G modem.

HDMI 2.0b and DisplayPort 1.4 interfaces, a USB Type-C port, three USB 3.2 Gen2 connectors, and a USB 2.0 port are provided. The active cooling system is on. Price - from 299 US dollars.

Other interesting news:

▪ Super solar flare could destroy all electronics on Earth

▪ The Polymer Diode Revolution Is Coming

▪ Tram without rails

▪ New membrane will reduce the cost of water filtration

▪ Washing with clean water

News feed of science and technology, new electronics

 

Interesting materials of the Free Technical Library:

▪ section of the site Data transfer. Article selection

▪ you can’t fool the article of the Shot Sparrow on the chaff. Popular expression

▪ article What are the benefits of snow? Detailed answer

▪ article Occupational safety promotion

▪ article Repair of mirrors. Simple recipes and tips

▪ article Papiros from the air. Focus Secret

Leave your comment on this article:

Name:


Email (optional):


A comment:





All languages ​​of this page

Home page | Library | Articles | Website map | Site Reviews

www.diagram.com.ua

www.diagram.com.ua
2000-2024