Menu English Ukrainian russian Home

Free technical library for hobbyists and professionals Free technical library


Instructions on labor protection for telegraph electromechanics. Full document

Occupational Safety and Health

Occupational Safety and Health / Standard instructions for labor protection

Comments on the article Comments on the article

Safe Operation

1. General requirements for labor protection

1.1. Persons not younger than 18 years of age, recognized as fit for production by a medical examination, having at least one year of work experience in these jobs and a telephone category of at least III, who have been trained and tested knowledge of the rules, norms and instructions on labor protection, including this instruction, as well as those who have a certificate for the right to carry out these works, who have received instructions at the workplace on safety during the performance of work.

1.2. The telegraph electrician must:

1.2.1. Comply with the rules of internal labor regulations;

1.2.2. Know and comply with the rules on labor protection when working at telephone enterprises in the scope of the duties performed, annually confirm the III electrical safety group;

1.2.3. Know the procedure for checking and using manual mechanical and power tools, devices to ensure safe work (ladders, ladders, etc.), protective equipment (dielectric gloves and carpets, tools with insulating handles, voltage indicators, safety glasses);

1.2.4. Perform only the work that is defined in the equipment operating instructions or job descriptions approved by the administration

1.2.5. enterprise, and provided that safe ways of doing it are well known;

1.2.6. Know and be able to provide first aid to victims of electric current and other accidents;

1.2.7. Follow the instructions on fire safety measures.

1.3. When servicing telegraph lines, the following hazardous and harmful production factors are possible:

  • dangerous voltage in the electrical circuit, the closure of which can occur through the human body, electric shock, electric arc burn;
  • penetration of explosive gases through the mine;
  • the occurrence of harmful substances (gasoline vapors, lead aerosols);
  • low air humidity and high temperature;
  • insufficient illumination of the working area;
  • fire hazard;
  • falling from a height of personnel while working on ladders and ladders;
  • falling objects from a height (tools, equipment elements).

1.4. The victim or eyewitness immediately notifies the immediate supervisor of each accident at work.

1.5. The telegraph electrician is responsible for the preparation of the workplace, including, but not limited to, carrying out work without removing the voltage.

1.6. For non-compliance with this instruction, the perpetrators are held accountable in accordance with the internal labor regulations or penalties determined by the Labor Code of the Russian Federation.

2. Labor protection requirements before starting work

2.1. Put on and carefully tuck in the special clothing (dressing gown) and technological footwear established in accordance with current standards, avoiding hanging ends and constraint when moving.

2.2. Check and verify the availability and serviceability of the fixed tool, devices to ensure safe work performance, personal protective equipment, fire extinguishing equipment.

2.3. Check the condition of general and ordinary lighting.

2.4. Do not carry out any work on the repair of fixtures, equipment, etc., if this is not part of the employee's responsibilities.

2.5. Report all shortcomings and malfunctions found during the inspection at the workplace to the shift supervisor for taking measures to eliminate them completely.

2.6. Place the tool in the workplace with maximum ease of use, avoiding the presence of unnecessary items in the work area.

2.7. Check the availability of a first aid kit.

3. Labor protection requirements during work

3.1. Work only in serviceable and carefully fitted overalls and safety shoes and use personal protective equipment required at the workplace in accordance with current standards.

3.2. Maintenance of devices located in the upper parts of the cabinets should be carried out only from serviceable marked stepladders.

3.3. It is necessary to install the stepladder firmly, checking its stability before lifting. Ladders with a height of 1,3 m or more must be equipped with a stop.

3.4. It is forbidden to work from the top two steps of stepladders that do not have railings or stops, as well as to be on the steps by more than one person.

3.5. The replacement of signal lamps on the scoreboard should be carried out from ladders with a height of at least 2 m.

3.6. Do not leave loose objects on the ladders and throw them down.

3.7. Movable ladders (ladders) with upper roller sliding, used when working in two-tiered crosses, must be secured with stoppers.

3.8. Changing individual fuses should be done with only one hand, and the second or part of the body should not touch grounded structures.

3.9. The replacement of an ordinary fuse must be carried out by two persons, one of whom is allowed to stand at the bottom of the stepladder, with the obligatory fulfillment of the requirements of clause 3.8., Use insulating pliers or dielectric gloves, safety glasses.

3.10. Pliers with insulating grips should be used when changing the individual fuses on the cabinet.

3.11. All repair work on the non-removable devices of the cabinets, cleaning of the mounting, safety frames, yells, etc., should be carried out with the cabinet fuses removed.

3.12. Equipment racks that have voltages greater than 42 V AC and 110 V DC should be provided with dielectric mats.

3.13. All enclosures and covers of equipment that cover 42 VAC contacts must display the electrical voltage symbol to alert service personnel to the danger of electrical shock.

3.14. Elimination of damage and repairs on the equipment must be carried out when the voltage is completely removed from the equipment.

3.15. The portable power tool used (soldering iron, step-down transformer) must be tested and have an inventory number, systematically and timely checked and repaired.

3.16. During an external examination of power tools and appliances, it is necessary to pay attention to the integrity of the insulation of the wires, the absence of bare current-carrying parts.

3.17. Checking for the absence of a short circuit to the case and the condition of the insulation must be carried out by a specially appointed person at least once every 1 months.

3.18. The passage between the front side of the power distribution equipment must be at least 1,2 m. There must be no foreign objects in the passage.

3.19. Dielectric mats should be placed on the side of opening doors of power cabinets and near the switchboard.

3.20. The length of the hose wire for connecting the step-down transformer to the network must not exceed 2 m.

3.21. Cases of portable household and measuring instruments, step-down transformers, displays and printers for a voltage of 220 V must be grounded.

3.22. For soldering, use electric soldering irons with a voltage not higher than 42 V.

3.23. It is necessary to use backlights for 60 V DC and not higher than 42 V AC, provided that the body of the backlight is made of insulating material and has a protective screen.

3.24. In the production of work on soldering devices with solder in the adjusting workshops, there should be special tables equipped with local suction (exhaust), electric lighting and a fire-resistant stand for a soldering iron, containers for alloys and fluxes.

3.25. When performing work on technological equipment, the presence of other workers in the immediate vicinity of the soldering point is prohibited.

Soldering processes are accompanied by air pollution with harmful substances. There is lead contamination of surfaces and skin of the hands, as well as the oral cavity.

When performing soldering at non-fixed workplaces, it is necessary to use trays to place soldering irons, solder and other materials on them.

3.26. Hands, clothes, shoes of personnel must always be dry

4. Labor protection requirements in emergency situations

4.1. Each employee who discovers violations of the requirements of this instruction and labor protection rules or notices a malfunction of the equipment that poses a danger to people is obliged to report this to the immediate supervisor.

In cases where a malfunction of the equipment poses a threatening danger to people or the equipment itself, the employee who discovered it is obliged to take measures to terminate the operation of the equipment, and then notify the immediate supervisor about this. Troubleshooting is carried out in compliance with safety requirements.

4.2. If an accident occurs during work, it is necessary to immediately provide first aid to the victim, report the incident to your immediate supervisor and take measures to preserve the situation of the accident, if this is not associated with a danger to life and health of people.

4.3. In case of electric shock, it is necessary to release the victim from the action of the current as soon as possible, in case of working at height, take measures to prevent him from falling. Switch off the equipment using switches, a plug-in connector, cut the supply wire with a tool with insulated handles. If it is impossible to turn off the equipment quickly enough, other measures must be taken to free the victim from the action of the current.

To separate the victim from current-carrying parts or wires, use a stick, board or some other dry object that does not conduct electricity, while the caregiver must stand on a dry, non-conductive place, or wear dielectric gloves.

4.4. If a fire occurs in a technical room, you should immediately start extinguishing it with the available means (carbon dioxide fire extinguishers, asbestos blankets, sand) and call the fire department.

4.5. If extraneous voltage is detected at the workplace, it is necessary to immediately stop work and report to the shift supervisor.

4.6. In the event of a power failure while working with a power tool or a break in work, the power tool must be "Unplugged".

5. Labor protection requirements at the end of work

5.2. It is necessary to tidy up the workplace, tools and fixtures.

5.3. Inform the shifter (shift supervisor) of all malfunctions noticed during work and the measures taken to eliminate them

5.4. Put away overalls (robe and slippers) in a specially designated place.

5.5. Wash your face and hands thoroughly with warm water and soap, rinse your mouth well. In the case of performing work related to soldering with alloys containing lead, it is imperative to neutralize lead with a 1% solution of acetic acid or OP-7 paste before washing hands.

 We recommend interesting articles Section Standard instructions for labor protection:

▪ Work on the compressor unit. Standard instruction on labor protection

▪ Electrical measurements and tests. Standard instruction on labor protection

▪ Car gas station operator. Standard instruction on labor protection

See other articles Section Standard instructions for labor protection.

Read and write useful comments on this article.

<< Back

Latest news of science and technology, new electronics:

Artificial leather for touch emulation 15.04.2024

In a modern technology world where distance is becoming increasingly commonplace, maintaining connection and a sense of closeness is important. Recent developments in artificial skin by German scientists from Saarland University represent a new era in virtual interactions. German researchers from Saarland University have developed ultra-thin films that can transmit the sensation of touch over a distance. This cutting-edge technology provides new opportunities for virtual communication, especially for those who find themselves far from their loved ones. The ultra-thin films developed by the researchers, just 50 micrometers thick, can be integrated into textiles and worn like a second skin. These films act as sensors that recognize tactile signals from mom or dad, and as actuators that transmit these movements to the baby. Parents' touch to the fabric activates sensors that react to pressure and deform the ultra-thin film. This ... >>

Petgugu Global cat litter 15.04.2024

Taking care of pets can often be a challenge, especially when it comes to keeping your home clean. A new interesting solution from the Petgugu Global startup has been presented, which will make life easier for cat owners and help them keep their home perfectly clean and tidy. Startup Petgugu Global has unveiled a unique cat toilet that can automatically flush feces, keeping your home clean and fresh. This innovative device is equipped with various smart sensors that monitor your pet's toilet activity and activate to automatically clean after use. The device connects to the sewer system and ensures efficient waste removal without the need for intervention from the owner. Additionally, the toilet has a large flushable storage capacity, making it ideal for multi-cat households. The Petgugu cat litter bowl is designed for use with water-soluble litters and offers a range of additional ... >>

The attractiveness of caring men 14.04.2024

The stereotype that women prefer "bad boys" has long been widespread. However, recent research conducted by British scientists from Monash University offers a new perspective on this issue. They looked at how women responded to men's emotional responsibility and willingness to help others. The study's findings could change our understanding of what makes men attractive to women. A study conducted by scientists from Monash University leads to new findings about men's attractiveness to women. In the experiment, women were shown photographs of men with brief stories about their behavior in various situations, including their reaction to an encounter with a homeless person. Some of the men ignored the homeless man, while others helped him, such as buying him food. A study found that men who showed empathy and kindness were more attractive to women compared to men who showed empathy and kindness. ... >>

Random news from the Archive

A revolution in exploration 06.08.2017

American scientists said they have developed a fundamentally new system for detecting any, even yet unknown to mankind, minerals, which is based on the use of huge amounts of accumulated data and network theory.

An example of the operation of network theory can be a diagram of the relationship between individual people in a particular situation, for example, infectious disease specialists thus reveal the extent and area of ​​the spread of a disease, starting to draw up a diagram of its spread from the primary patient to subsequent carriers.

By using a similar networking approach, coupled with available data and mapping, geologists can discover new, yet unknown deposits of the most valuable minerals at a scale and at a speed that was previously inaccessible to mankind.

Now it is known about the existence of more than 5 minerals on Earth, each of which has a completely unique structure peculiar only to this element. The new method makes it possible to map all these minerals in the places where they were found around the world, thus revealing some patterns and relationships.

This approach has the potential to revolutionize exploration, as well as discover new rare minerals that could be useful in various fields of human activity - from innovative technologies to rocket science.

This technology has already been used in the identification of 145 coal-bearing minerals and the discovery of their deposits.

Other interesting news:

▪ Traffic lights will soon disappear from the roads

▪ Fastest laptop graphics processor from Nvidia

▪ Panic among mice

▪ Surface defrosting in a second

▪ Identification of the owner of a mobile phone by fingerprint

News feed of science and technology, new electronics

 

Interesting materials of the Free Technical Library:

▪ section of the site Aphorisms of famous people. Article selection

▪ article Do with us, do as we do, do better than us! Popular expression

▪ article What human bone inspired Eiffel to design the Eiffel Tower? Detailed answer

▪ article Senior Process Engineer. Job description

▪ article Gilding of metals. Simple recipes and tips

▪ article Laboratory power supply, 220/12,5 volts 5 amps. Encyclopedia of radio electronics and electrical engineering

Leave your comment on this article:

Name:


Email (optional):


A comment:





All languages ​​of this page

Home page | Library | Articles | Website map | Site Reviews

www.diagram.com.ua

www.diagram.com.ua
2000-2024