Instructions on labor protection when working on rack-mount communication lines and when hanging communication cables. Full document Occupational Safety and Health / Standard instructions for labor protection Safe Operation 1. General requirements for labor protection 1.1. Persons at least 18 years of age who have passed a medical examination are allowed to work on rack communication lines and cable suspension. introductory briefing and briefing at the workplace. 1.2. An electrician, when servicing rack communication lines and when hanging cables, before being assigned to independent work, must undergo training in safe working methods in the amount of: 1.2.1. Technologies of work. 1.2.2. Rules on labor protection when working on overhead and cable communication lines; 1.2.3. Application of means of protection; 1.2.4. Providing first aid; 1.2.5. Rules of the road. 1.3. Upon completion of training, the electrician passes a test of knowledge of labor protection rules with the assignment of a qualification group for electrical safety not lower than III, and then annually confirms it. 1.4. When servicing rack communication lines and hanging cables, the following hazardous and harmful production factors are possible: 1.4.1. Work with electrical installations (electric shock, electric shock, electric arc burn); 1.4.2. Work near and at intersections with overhead power lines, contact networks of land transport and wire broadcasting; 1.4.3. Work in the area of traffic and people; 1.4.4. Unfavorable meteorological conditions (low air temperature, high humidity, etc.); 1.4.5. Work at height. 1.5. Work on linear communication facilities on the street is prohibited: 1.5.1. During a thunderstorm and its approach; 1.5.2. With snowstorms, sandstorms and wind speeds above 15 m/s (when the wind speed is 15-18 m/s, thin branches and dry branches of trees break); 1.5.3. When the air temperature is below the norms established by the regulations of local authorities; 1.6. When servicing rack communication lines, an electrician is obliged to: 1.6.1. Perform only the work that is defined by job descriptions, and on the condition that he is well aware of the safe ways of doing it; 1.6.2. Comply with the rules of internal labor regulations and labor protection; 1.6.3. If extraneous voltage is detected on the line, immediately stop work and report to your immediate supervisor, inform the repair bureau and take measures to exclude the possibility of contact by unauthorized persons; 1.6.4. Follow this instruction; 1.7. In case of injury or indisposition of the worker, it is necessary to notify the supervisor and contact the first-aid post. 1.8. For non-compliance with this instruction, the perpetrators are held accountable in accordance with the internal labor regulations or penalties determined by the Code of Labor Laws of the Russian Federation. 2. Labor protection requirements before starting work 2.1. Get instructions on safety measures when working in hazardous areas from the foreman, understand the assignment received. 2.2. Select the necessary tools, devices and protective equipment to perform this work, make sure that they are in good condition. 2.3. To carry the working tool, use a special bag or suitcase. 2.4. Put on and carefully fit special clothing, not allowing the floors to be open, but not restricting movement. 3. Labor protection requirements during work 3.1. Work on the rack lines is carried out only with a safety belt, helmets and shoes with rubber soles or galoshes. 3.2. When working at heights and works related to laying cables along the walls of buildings, you need to use serviceable wooden stairs, ladders, scaffolds and aerial platforms: 3.3. Before entering the iron roof, the employee is obliged to check with the indicator the absence of voltage on all metal objects encountered along the route of his path through the attic, and before entering the roof - on the metal ladder, the roof itself and the safety belt. If voltage is detected, access to the roof is prohibited. An employee who detects voltage is obliged to notify the employees of the house management and the technical manager of his enterprise about this. 3.4. The dimensions (in meters) of rack lines, depending on the class of wired broadcasting, are indicated below:
3.5. The intersection of the wires of the rack lines of the GTS and PV contact wires, electrified with direct current, railways, trams, trolleybuses, power lines up to 1000 V must be made with insulated wires with weather-resistant insulation. Splicing of these wires in the span is not allowed. 3.6. The crossing of electrified railways with alternating current should be carried out only by an underground cable. 3.7. When hanging a feeder with a voltage above 360 V on metal racks on the roofs of houses, it is necessary to make grounded racks, which should be grounded using a suspended steel wire with a diameter of 4 mm, connected to the stem of the racks and grounded every two km. 3.8. Cable supports must be equipped with a cable platform, traverses, steps, lightning rod and grounding. The underground cable brought to the cable support must be protected from mechanical damage; down conductors that do not have a gap are closed along the entire length of the support with a wooden lath. The value of ground resistance must comply with GOST 464 3.9. If there is a remote supply voltage on the wires suitable for the cable support, the circuits are tested in dielectric gloves and dielectric galoshes. Repair work in the cable box or hanging NUP must be carried out with the remote power removed. 3.10. The absence of extraneous dangerous voltage on the torso and cable should be checked. Check with a voltage indicator. To check the presence of extraneous voltage on the cables and cables of the communication line and wire broadcasting, which have overhead intersections with power lines with voltages above 1000 V, it is necessary to use high-voltage indicators. After it is established that there is no extraneous voltage above 1000 V on the cables and cables of communication and wire broadcasting, using a low voltage indicator, you must make sure that there is also no extraneous voltage below 1000 V on the cables and cables of communication and wire broadcasting. only one low voltage indicator of the type INN-1 to determine the presence of extraneous voltage on cables and cables for communication and wire broadcasting that intersect with power lines with voltages above 1000 V is prohibited 3.11. It is forbidden to work on a cable support when approaching or during a thunderstorm, with a wind of more than 15 m per second, during snowstorms. 3.12. On overhead cable communication lines and wire broadcasting, the steel cable to which the cable is suspended must be grounded. 4. Labor protection requirements in emergency situations 4.1. In the event of accidents or situations that can lead to accidents and accidents, you should: 4.1.1. Immediately stop work and notify the person responsible for the work; 4.1.2. Under the guidance of the person responsible for the production of works or personally to the electrician, take measures to eliminate the causes of accidents or accidents; 4.1.3. About victims of accidents (injured) or those who have undergone a sudden illness, it is necessary to notify the head, report to the first-aid post and take measures to provide the necessary first aid. 5. Labor protection requirements at the end of work 5.1. At the end of the work, the electrician must: 5.1.1. Tell the person. responsible for the completion of work, and about all the shortcomings noticed during the work and the measures taken to eliminate them. 5.1.2. Clean and tidy work area. 5.1.3. Deliver tools and accessories to the main place of work. 5.1.4. Remove overalls, wash hands with soap and water, take a shower. We recommend interesting articles Section Standard instructions for labor protection: ▪ Brand manager. Standard instruction on labor protection ▪ Helicopter crew. Standard instruction on labor protection See other articles Section Standard instructions for labor protection. Read and write useful comments on this article. Latest news of science and technology, new electronics: Artificial leather for touch emulation
15.04.2024 Petgugu Global cat litter
15.04.2024 The attractiveness of caring men
14.04.2024
Other interesting news: ▪ Thoughts are recognized and recorded ▪ Highscreen Alpha R Full HD smartphone with a week of battery life ▪ Headset Thermaltake RIING Pro RGB 7.1 ▪ Leaf cutter ants produce laughing gas ▪ Car tires with living moss inside News feed of science and technology, new electronics
Interesting materials of the Free Technical Library: ▪ section of the site Note to the student. Article selection ▪ article How does anyone bake pancakes. Popular expression ▪ article How does light travel? Detailed answer ▪ article Convulsions. Health care ▪ Refrigerator machine article. Encyclopedia of radio electronics and electrical engineering ▪ article Simple UMZCH. Encyclopedia of radio electronics and electrical engineering
Leave your comment on this article: All languages of this page Home page | Library | Articles | Website map | Site Reviews www.diagram.com.ua |