ENCYCLOPEDIA OF RADIO ELECTRONICS AND ELECTRICAL ENGINEERING
Section 1 General Rules Accounting for electricity. Technical accounting Encyclopedia of radio electronics and electrical engineering / Rules for the installation of electrical installations (PUE) 1.5.39. At thermal and nuclear power plants with units (units) that are not equipped with information or control computers, stationary or portable inventory meters for technical accounting in the SN system should be installed in order to be able to calculate technical and economic indicators. In this case, the installation of active electricity meters should be carried out in the circuits of electric motors powered from the buses of the main voltage switchgear (above 1 kV) for auxiliary needs, and in the circuits of all transformers powered from these buses. 1.5.40. At power plants with cross connections (having a common steam line), it must be provided on the generator voltage side of the transformers exceeding the technical possibility of installing (under operating conditions) meters for technical metering of active electricity, used to monitor the correct operation of the calculated generator meters. 1.5.41. Active electricity meters for technical accounting should be installed at substations with a voltage of 35 kV and above power systems: on the medium and low voltage sides of power transformers; on each outgoing power transmission line of 6 kV and above, which is on the balance of the power system. Reactive electricity meters for technical accounting should be installed on the medium and low voltage sides of power transformers of substations of 35 kV and above power systems. The specified requirements for the installation of electricity meters are subject to implementation as meters are provided. 1.5.42. Enterprises should provide for the technical possibility of installing (under operating conditions) stationary or using inventory portable meters to monitor compliance with energy consumption limits in workshops, production lines, and individual energy-intensive units, to determine energy consumption per unit of product or semi-finished product. It is allowed to install technical metering meters at the input of an enterprise if settlement accounting with this enterprise is carried out using meters installed at substations or power plants of energy systems. The installation and removal of technical metering meters at enterprises does not require permission from the energy supply organization. 1.5.43. Technical metering devices at enterprises (meters and instrument transformers) must be under the control of consumers themselves and must meet the requirements of 1.5.13 (with the exception of the requirement for a seal from the energy supply organization), 1.5.14 and 1.5.15. 1.5.44. The accuracy classes of meters for technical metering of active electricity must correspond to the values given below:
The accuracy classes of meters for technical metering of reactive electricity can be selected one step lower than the corresponding accuracy class of meters for technical metering of active electricity. See other articles Section Rules for the installation of electrical installations (PUE). Read and write useful comments on this article. Latest news of science and technology, new electronics: The world's tallest astronomical observatory opened
04.05.2024 Controlling objects using air currents
04.05.2024 Purebred dogs get sick no more often than purebred dogs
03.05.2024
Other interesting news: ▪ OKI LED printer with white toner ▪ CRT TV with built-in DVD recorder from PANASONIC ▪ Signature size and narcissism News feed of science and technology, new electronics
Interesting materials of the Free Technical Library: ▪ section of the site Electronic directories. Article selection ▪ article Infectious diseases. Basics of safe life ▪ article How old is dentistry? Detailed answer ▪ article Measurement by angular values of objects. Travel Tips ▪ article LED voltage indicator. Encyclopedia of radio electronics and electrical engineering ▪ article Spectators can't guess which hand the coin is in. Focus Secret
Leave your comment on this article: All languages of this page Home page | Library | Articles | Website map | Site Reviews www.diagram.com.ua |