ENCYCLOPEDIA OF RADIO ELECTRONICS AND ELECTRICAL ENGINEERING
Section 3. Electrical installations for special purposes Chapter 3.2. Electrothermal installations. Electrode boilers Encyclopedia of radio electronics and electrical engineering / Rules for the technical operation of consumer electrical installations (PTE) 3.2.46. These requirements apply to electrode hot water and steam boilers, regardless of the operating pressure and temperature of heating water in them, powered by industrial frequency current sources with voltage up to and above 1000 V, intended for heating systems, hot water and steam supply for residential, domestic, public and industrial buildings, structures, industrial and agricultural installations. 3.2.47. Only electrode boilers manufactured in organizations that have the technical means to ensure that their quality meets the requirements of state standards or technical specifications agreed in the prescribed manner are allowed to be put into operation. 3.2.48. Electrode boilers and pipelines must be thermally insulated from a material with a low specific gravity and low thermal conductivity. The temperature of the outer surface of the insulation should not exceed 55 °C. 3.2.49. Electrode boilers must be installed in a separate room. Technological equipment and protection and automation devices can be located in the same room. Electrode boilers with voltage up to 1000 V can be installed in industrial premises together with other equipment. Drainage devices must be provided in the boiler room to ensure emergency and repair water discharge from the heating or hot water supply system. 3.2.50. In an electric boiler room with a voltage above 1000 V, a separate room for electrical personnel should be provided. In the same room, a telecontrol and telemetering console, as well as protection and automation devices, can be installed. 3.2.51. Based on the need to equalize the energy consumption graph, it is not allowed to operate electrode boilers in heating systems that do not have ballasts. Electrode boilers must be equipped with automation devices that turn them off in accordance with a given work schedule. 3.2.52. Electrode steam boilers with voltages above 1000 V are allowed to operate after they have been registered, checked and tested in the prescribed manner. 3.2.53. Electrode boilers can operate without constant personnel duty if there are automatic and remote control devices that ensure the normal operation of electrode boilers automatically or from the control panel, as well as with protection that ensures the boiler stops in case of violation of operating modes with a signal to the control panel. In this case, it must be possible to stop the boiler from the control panel. 3.2.54. Power regulation of electrode boilers under voltage is not allowed. 3.2.55. The electrode boiler must be switched off immediately when: type="disc">The local production instructions should also indicate the procedure for eliminating the emergency condition and starting the electrode boilers. 3.2.56. For each boiler with a voltage above 1000 V installed in the boiler room, a log must be kept in which the date, type of repair, inspection results, information about replacement parts, data on emergencies, etc. are entered. 3.2.57. Inspection of electrode boilers with voltage up to 1000 V is carried out before each heating season, and with voltage above 1000 V - with a certain frequency established by the schedule, but at least once a month. Inspection is carried out in accordance with the requirements of the local production instructions approved by the consumer responsible for the electrical equipment. The results of the inspection and measures to eliminate malfunctions are recorded in a log signed by the employee who conducted the inspection. 3.2.58. Scheduled preventive maintenance is carried out at intervals established for boilers with a voltage above 1000 V by a special schedule, but at least 1 time in 6 months. For boilers with voltage up to 1000 V, the need for scheduled preventive maintenance is determined by the technical manager of the Consumer or the organization conducting the repair. 3.2.59. Preventive tests and measurements on electrode boilers must be carried out in accordance with the standards for testing electrical equipment (Appendix 3). See other articles Section Rules for the technical operation of consumer electrical installations (PTE). Read and write useful comments on this article. Latest news of science and technology, new electronics: A New Way to Control and Manipulate Optical Signals
05.05.2024 Primium Seneca keyboard
05.05.2024 The world's tallest astronomical observatory opened
04.05.2024
Other interesting news: ▪ Plasma accelerator for plants ▪ Solar panels LG NeON R and NeON R Prime ▪ Living synthetic cells created News feed of science and technology, new electronics
Interesting materials of the Free Technical Library: ▪ section of the site Funny puzzles. Article selection ▪ article There is a smell of thunder in the air. Popular expression ▪ article Which satellite overtakes its planet in its rotation around its own axis? Detailed answer ▪ article Kosmey. Legends, cultivation, methods of application ▪ article Stretched knot. Focus Secret
Leave your comment on this article: All languages of this page Home page | Library | Articles | Website map | Site Reviews www.diagram.com.ua |