Instruction on labor protection for the adjuster of instrumentation and automation Occupational Safety and Health / Standard instructions for labor protection Safe Operation 1. General requirements for labor protection 1.1. Persons at least 18 years of age who have undergone a medical examination, have been trained in safe working methods, have passed a knowledge test of labor protection requirements, have at least one year of work experience in these jobs and have an electrical safety group of at least IV , as well as having a certificate for the right to carry out these works, who received instructions at the workplace on safety during the performance of work. 1.2. The adjuster of instrumentation and equipment is obliged to: 1.2.1. observe the rules of internal labor regulations; 1.2.2. to know the device of input transformers, substations, transitional cabinets, schemes for laying electrical cables, their malfunctions and ways to eliminate them; 1.2.3. competently operate and timely conduct preventive inspections and repairs of power equipment; 1.2.4. monitor the good condition of starting and protective electrical equipment, grounding (zeroing) of instrumentation and equipment;. 1.2.5. know and comply with the rules on labor protection during the adjustment and repair of instrumentation and the scope of duties performed, annually confirm the IV electrical safety group; 1.2.6. know the procedure for checking and using manual mechanical and power tools, devices for ensuring safe work (ladders, ladders, etc.), protective equipment (dielectric gloves and carpets, tools with insulating handles, voltage indicators, safety glasses); 1.2.7. perform only the work that is defined in the operating instructions for the equipment or job descriptions approved by the administration of the enterprise, and provided that safe methods of doing it are well known; 1.2.8. know and be able to provide first aid to victims of electric current and other accidents; 1.2.9. follow the instructions on fire safety measures. 1.3. When servicing instrumentation and equipment, the following hazardous and harmful production factors are possible:
1.4. The administration of the enterprise is obliged to provide the serviceman working with electrical equipment with overalls, safety shoes and PPE in accordance with industry standards. 1.5. The victim or eyewitness immediately notifies the immediate supervisor of each accident at work. 1.6. The I&C service technician is the person responsible for the preparation of the workplace, including, but not limited to, carrying out work without removing the voltage. 1.7. For non-compliance with this instruction, the perpetrators are held accountable in accordance with the internal labor regulations or penalties determined by the Labor Code of the Russian Federation. 2. Labor protection requirements before starting work 2.1. Put on and carefully tuck in the special clothing (dressing gown) and special footwear established in accordance with current standards, avoiding hanging ends and constraint when moving. 2.2. Check and verify the availability and serviceability of the fixed tool, devices to ensure safe work performance, personal protective equipment, fire extinguishing equipment. 2.3. Check the condition of general and ordinary lighting. 2.4. Do not carry out any work on the repair of fixtures, equipment, etc., if this is not part of the employee's responsibilities. 2.5. Report all shortcomings and malfunctions found during the inspection at the workplace to the shift supervisor for taking measures to eliminate them completely. 2.6. Place the tool in the workplace with maximum ease of use, avoiding the presence of unnecessary items in the work area. 2.7. Check the availability of a first aid kit. 3. Labor protection requirements during work 3.1. Work only in serviceable and carefully fitted overalls and safety shoes and use personal protective equipment required at the workplace in accordance with current standards. 3.2. When servicing and repairing electrical installations, the use of metal ladders is prohibited. Work using ladders is performed by two persons, one of which is located below. Work with boxes and other foreign objects is prohibited. 3.3. It is necessary to install the stepladder firmly, checking its stability before lifting. Ladders with a height of 1,3 m or more must be equipped with a stop. 3.4. It is forbidden to work from the top two steps of stepladders that do not have railings or stops, as well as to be on the steps by more than one person. 3.5. Do not leave loose objects on the ladders and throw them down. 3.6. Changing individual fuses should be done with only one hand, and the second or part of the body should not touch grounded structures. 3.7. The replacement of an ordinary fuse must be carried out by two workers, one of whom must stand at the bottom of the stepladder, with the obligatory fulfillment of the requirements of clause 3.8, use insulating pliers or dielectric gloves, goggles. 3.8. All repair work on instrumentation and instrumentation A preventive inspection, repair should be carried out with the fuses (voltage) removed. Check the absence of voltage on current-carrying parts of electrical equipment with a voltmeter or voltage indicator. 3.9. To protect against burns when changing lamps in the equipment, the service technician must use cotton gloves, special keys and fixtures. 3.10. After removing the remote supply voltage, it is necessary to remove the residual charge from the cable cores and ground them. This work is carried out in dielectric gloves, dielectric galoshes and with the use of goggles. 3.11. Immediately after carrying out the necessary shutdowns on the switching equipment (machine, knife switch, switch) disconnected during the preparation of the workplace, posters should be posted: "Do not turn on - people work!", And disconnected for admission to work on overhead lines and cable lines - posters: "Do not turn on - work on the line!". 3.12. During simultaneous work on the line and the line disconnector in the electrical installation to which the line disconnector belongs, posters: "Do not turn on! Work on the line" - are hung on the drives of the disconnectors closest to the circuit, which can supply voltage to the line disconnector. 3.13. For work, use a hand tool with insulating handles (pliers, pliers, wire cutters, screwdrivers), the dielectric coating should not be damaged and fit snugly to the handle. 3.9. Elimination of damage and repairs on the equipment must be carried out when the voltage is completely removed from the equipment. 3.10. The portable power tool used (soldering iron, step-down transformer) must be tested and have an inventory number, systematically and timely checked and repaired. 3.11. During an external examination of power tools and appliances, it is necessary to pay attention to the integrity of the insulation of the wires, the absence of bare current-carrying parts. 3.12. Dielectric mats should be placed on the side of opening doors of power cabinets and near the switchboard. 3.13. Cases of portable household and measuring instruments, step-down transformers, displays and printers for a voltage of 220 V must be grounded. 3.14. For soldering, use electric soldering irons with a voltage not higher than 42 V. 3.15. In the production of work on soldering devices with solder in the adjusting workshops, there should be special tables equipped with local suction (exhaust), electric lighting and a fire-resistant stand for a soldering iron, containers for alloys and fluxes. 4. Labor protection requirements during work 3.16. Each employee who discovers violations of the requirements of this instruction and labor protection rules or notices a malfunction of the equipment that poses a danger to people is obliged to report this to the immediate supervisor. In cases where a malfunction of the equipment poses a threatening danger to people or the equipment itself, the employee who discovered it is obliged to take measures to terminate the operation of the equipment, and then notify the immediate supervisor about this. Troubleshooting is carried out in compliance with safety requirements. 3.17. If an accident occurs during work, it is necessary to immediately provide first aid to the victim, report the incident to your immediate supervisor and take measures to preserve the situation of the accident, if this is not associated with a danger to life and health of people. 3.18. In case of electric shock, it is necessary to release the victim from the action of the current as soon as possible, in case of working at height, take measures to prevent him from falling. Switch off the equipment using switches, a plug-in connector, cut the supply wire with a tool with insulated handles. If it is impossible to turn off the equipment quickly enough, other measures must be taken to free the victim from the action of the current. To separate the victim from current-carrying parts or wires, use a stick, board or some other dry object that does not conduct electricity, while the caregiver must stand on a dry, non-conductive place, or wear dielectric gloves. 3.19. If a fire occurs in a technical room, you should immediately start extinguishing it with the available means (carbon dioxide fire extinguishers, asbestos blankets, sand) and call the fire department. 3.20. In the event of a power failure while working with a power tool or a break in work, the power tool must be "Unplugged". 4. Labor protection requirements at the end of work 4.1. It is necessary to tidy up the workplace, tools and fixtures. 4.2. Notify the work manager of any malfunctions noticed during work and the measures taken to eliminate them 4.3. Clothing must be put away in a designated area. 4.4. Wash your face and hands thoroughly with warm water and soap, and take a shower. We recommend interesting articles Section Standard instructions for labor protection: ▪ Trailer grader operator. Standard instruction on labor protection See other articles Section Standard instructions for labor protection. Read and write useful comments on this article. Latest news of science and technology, new electronics: Artificial leather for touch emulation
15.04.2024 Petgugu Global cat litter
15.04.2024 The attractiveness of caring men
14.04.2024
Other interesting news: ▪ Scientists believe that global warming has become irreversible ▪ Ford smart suspension with pothole protection ▪ MOTOROLA taught TVs to understand human speech News feed of science and technology, new electronics
Interesting materials of the Free Technical Library: ▪ website section LEDs. Article selection ▪ article Once lied, who will believe you? Popular expression ▪ article What is temperature inversion? Detailed answer ▪ article Astragalus. Legends, cultivation, methods of application ▪ article Electrotechnical sheet steel. Encyclopedia of radio electronics and electrical engineering
Leave your comment on this article: All languages of this page Home page | Library | Articles | Website map | Site Reviews www.diagram.com.ua |