ENCYCLOPEDIA OF RADIO ELECTRONICS AND ELECTRICAL ENGINEERING Car starter. Encyclopedia of radio electronics and electrical engineering Encyclopedia of radio electronics and electrical engineering / car The use of a starting device will be especially useful for car enthusiasts who operate a car in the winter season, as it extends battery life and also allows you to start a cold car in winter without problems, even with an incompletely charged battery. It is known from experience that at sub-zero temperatures, the battery reduces its return by 25 ... 40%. And if it is not yet fully charged, it will not be able to provide the initial current of 200 A required to start the engine. This current is consumed by the starter at the initial moment of spinning the engine shaft (the rated current consumption of the starter is about 80 A, but at the time of starting it is much more). The simplest calculations show that in order for the starting device to work effectively when connected in parallel with the battery, it must provide a current of at least 100 A at a voltage of 10 ... 14 V. In this case, the rated power of the used network transformer T1 (Fig. 4.1) must be at least 800 watts. As you know, the rated operating power of the transformer depends on the cross-sectional area of the magnetic circuit (iron) at the location of the windings.
The starting device circuit itself is quite simple, but requires the correct manufacture of a network transformer. For it, it is convenient to use toroidal iron from any LATRA - in this case, the minimum dimensions and weight of the device are obtained. The perimeter of the iron section can be from 230 to 280 mm (it differs for different types of autotransformers). Before winding the windings, it is necessary to round off the sharp edges on the edges of the magnetic circuit with a file, after which we wrap it with varnished cloth or fiberglass. The primary winding of the transformer contains approximately 260 ... 290 turns of PEV-2 wire with a diameter of 1,5 ... 2,0 mm (the wire can be of any type with varnish insulation). The winding is distributed evenly in three layers, with interlayer insulation. After completing the primary winding, the transformer must be connected to the network and the no-load current must be measured. It should be 200...380 mA. In this case, there will be optimal conditions for transforming power into a secondary circuit. If the current is less, part of the turns must be unwound, if more, wind up until the specified value is obtained. It should be borne in mind that the relationship between the inductive reactance (and hence the current in the primary winding) and the number of turns is quadratic - even a slight change in the number of turns will lead to a significant change in the current of the primary winding. When the transformer is in idle mode, there should be no heating. The heating of the winding indicates the presence of interturn short circuits or the punching and closing of part of the winding through the magnetic circuit. In this case, the winding will have to be done again. The secondary winding is wound with an insulated stranded copper wire with a cross section of at least 6 mm2 (for example, type PVKV with rubber insulation) and contains two windings of 15 ... 18 turns. The secondary windings are wound simultaneously (with two wires), which makes it easy to obtain their symmetry - the same voltage in both windings, which should be in the range of 12 ... 13,8 V at a nominal mains voltage of 220 V. It is better to measure the voltage in the secondary winding temporarily a load resistor with a resistance of 2 ... 3 Ohm connected to terminals X5, X10. The connection of rectifier diodes shown in the diagram makes it possible to use the metal elements of the body of the starting device not only for fastening diodes, but also as a heat sink without dielectric spacers ("plus" of the diode is connected to the mounting nut). To connect the starting device in parallel with the battery, the connecting wires must be insulated and stranded (preferably copper), with a cross section of at least 10 mm2 (not to be confused with the diameter). At the ends of the wire, after tinning, the connecting tips are soldered. The contacts of the switch S1 must be rated for a current of at least 5 A. Author: Shelestov I.P. See other articles Section car. Read and write useful comments on this article. Latest news of science and technology, new electronics: Artificial leather for touch emulation
15.04.2024 Petgugu Global cat litter
15.04.2024 The attractiveness of caring men
14.04.2024
Other interesting news: ▪ Budget Smartphone Coolpad Cool 20s ▪ Newspapers and the Internet: An Ecologist's Perspective ▪ Panasonic E3 Rugged Student Tablet ▪ Ball lightning - maybe it's just an illusion News feed of science and technology, new electronics
Interesting materials of the Free Technical Library: ▪ site section Low frequency amplifiers. Article selection ▪ article Emergencies in case of accidents at chemically hazardous facilities. Basics of safe life ▪ article Why do some people have dwarfish growth? Detailed answer ▪ article Anti-terrorism security and protection of children. Standard instruction on labor protection
Leave your comment on this article: Comments on the article: MB How to use a welding transformer as a starting device for a car? All languages of this page Home page | Library | Articles | Website map | Site Reviews www.diagram.com.ua |