Menu English Ukrainian russian Home

Free technical library for hobbyists and professionals Free technical library


ENCYCLOPEDIA OF RADIO ELECTRONICS AND ELECTRICAL ENGINEERING
Free library / Schemes of radio-electronic and electrical devices

Refinement of the frequency meter control unit. Encyclopedia of radio electronics and electrical engineering

Free technical library

Encyclopedia of radio electronics and electrical engineering / Measuring technology

Comments on the article Comments on the article

In N. Kovalev's article "Frequency meter control unit" ("Radio", 1996, No. 3, pp. 55, 56), a good idea was given to combine an electronic switch and a frequency meter control unit and options for implementing this idea were described. And yet, a certain disadvantage of the node, in my opinion, is the lack of a mode for measuring the period of pulses. Such a mode is necessary, for example, when measuring signals of very low frequency, when using various attachments to the frequency meter, in which the repetition period of the output pulses is directly proportional to the value of one or another measured physical quantity (capacitor capacitance, for example).

This shortcoming can be easily corrected - it is enough to use a two-input adder modulo 3.1 EXCLUSIVE OR instead of the DD1 inverter (see Fig. 2 in the above article) and replace the measurement mode switch with another - with three groups of switching contacts for five positions (5PZN).

Such a replacement allows you to release one input (02) of the DD1.1 multiplexer (see the diagram shown here), to which a low logic level pulse with a duration equal to the period T of the measured signal (code name Fx / 2) must be applied.

Refinement of the frequency meter control unit
(click to enlarge)

The measured signal Fx is supplied to the upper input of the DD3.1 element according to the scheme, and the lower one is used to control the element. If the control input is connected to a common wire (in position 5 of the SA1 switch), then a low logic level will be set on it and the DD3.1 element will work as a repeater of the signal coming to the upper input. At a high level at the control input (positions 1 - 4 of the SA1 switch), the output signal of the DD3.1 element will be the inversion of the signal at the top input.

Thus, the frequency meter control unit with the above changes in positions 1 and 2 of switch SA1 allows you to measure the pulse frequency in the same way as in the article mentioned above, and in position 3 of the switch, low-level pulses with a period equal to period of the measured frequency. During the duration of the pulse, the switch allows the passage of pulses of the reference frequency Fo (from 1.2 Hz to 1 MHz). Their number will determine the counter as the period of the measured signal.

In positions 4 and 5 of the switch SA1, respectively, the measurement of the duration of the high and low logic level pulses takes place. This changes the mode of operation of only the DD3.1 element, and the operation of the multiplexers remains the same (it is described in the above article for positions 3 and 4 of the SA1 switch).

If the device has a free OR element, it is possible to organize the power-up of the Fx / 10 frequency divider only in position 1 of the SA1 switch. For this, a node is assembled, consisting of elements DD4.1, VT1, R6, C5.

The same effect will be obtained if the switch 5PZN (SA1) is replaced with 5P4N. The fourth section is included as shown in the diagram by dashed lines.

From the editor. In the described device, you can do without the SA1.1 section. To do this, you only need to change the inclusion of sections SA 1.2 and SA 1.3.

The terminals of the moving contacts of these sections "ground". Contacts 1 and 3 connected together (counting from top to bottom according to the diagram) of the SA 1.2 section are connected to the input 1 circuit of the DD1 switch, and contacts 1 and 2 of the SA1.3 section connected together to the input 2 circuit of the switch. Section SA1.1 is no longer needed - its role will be played by the lower fixed contact of section SA1.2, which must be connected to the place where the movable contact of section SA1.1 is output.

Author: A. Nemich, Bryansk; Publication: N. Bolshakov, rf.atnn.ru

See other articles Section Measuring technology.

Read and write useful comments on this article.

<< Back

Latest news of science and technology, new electronics:

Machine for thinning flowers in gardens 02.05.2024

In modern agriculture, technological progress is developing aimed at increasing the efficiency of plant care processes. The innovative Florix flower thinning machine was presented in Italy, designed to optimize the harvesting stage. This tool is equipped with mobile arms, allowing it to be easily adapted to the needs of the garden. The operator can adjust the speed of the thin wires by controlling them from the tractor cab using a joystick. This approach significantly increases the efficiency of the flower thinning process, providing the possibility of individual adjustment to the specific conditions of the garden, as well as the variety and type of fruit grown in it. After testing the Florix machine for two years on various types of fruit, the results were very encouraging. Farmers such as Filiberto Montanari, who has used a Florix machine for several years, have reported a significant reduction in the time and labor required to thin flowers. ... >>

Advanced Infrared Microscope 02.05.2024

Microscopes play an important role in scientific research, allowing scientists to delve into structures and processes invisible to the eye. However, various microscopy methods have their limitations, and among them was the limitation of resolution when using the infrared range. But the latest achievements of Japanese researchers from the University of Tokyo open up new prospects for studying the microworld. Scientists from the University of Tokyo have unveiled a new microscope that will revolutionize the capabilities of infrared microscopy. This advanced instrument allows you to see the internal structures of living bacteria with amazing clarity on the nanometer scale. Typically, mid-infrared microscopes are limited by low resolution, but the latest development from Japanese researchers overcomes these limitations. According to scientists, the developed microscope allows creating images with a resolution of up to 120 nanometers, which is 30 times higher than the resolution of traditional microscopes. ... >>

Air trap for insects 01.05.2024

Agriculture is one of the key sectors of the economy, and pest control is an integral part of this process. A team of scientists from the Indian Council of Agricultural Research-Central Potato Research Institute (ICAR-CPRI), Shimla, has come up with an innovative solution to this problem - a wind-powered insect air trap. This device addresses the shortcomings of traditional pest control methods by providing real-time insect population data. The trap is powered entirely by wind energy, making it an environmentally friendly solution that requires no power. Its unique design allows monitoring of both harmful and beneficial insects, providing a complete overview of the population in any agricultural area. “By assessing target pests at the right time, we can take necessary measures to control both pests and diseases,” says Kapil ... >>

Random news from the Archive

Battery wrench 09.06.2000

The American Joe Piccone created a sliding wrench, the jaw opening of which is changed by pressing a button: the screw that rearranges the movable sponge is rotated by a micromotor. Two XNUMX-volt batteries are hidden in the key handle.

It's only a prototype so far, but Piccone plans to start production in less than a year.

Other interesting news:

▪ Program for the construction of synthetic DNA

▪ Acer Predator X34 Gaming Monitor

▪ The fate of the handwritten letter

▪ Display controller ELSA Datapath FX4

▪ Concrete accumulators

News feed of science and technology, new electronics

Interesting materials of the Free Technical Library:

▪ section of the site for the Builder, home craftsman. Selection of articles

▪ article The morning greets us with coolness. Popular expression

▪ article Where can a governor approve a law passed by Parliament, completely changing its meaning? Detailed answer

▪ article Work on a cover-making machine such as KD-3, etc.. Standard instructions for labor protection

▪ article Low frequency limiter. Encyclopedia of radio electronics and electrical engineering

▪ article Those same words. Focus Secret

Leave your comment on this article:

Name: