1. General requirements for labor protection

1.1. Persons at least 18 years of age who are recognized as fit for production by a medical examination, have at least one year of work experience in these jobs and an electrical safety group of at least 3, who have been trained and tested knowledge of the rules, norms and instructions for protection, are allowed to work as a telecom operator labor, including this instruction, as well as having a certificate for the right to carry out these works, who have received instructions at the workplace on safety when performing work.

1.2. The telecom operator is obliged:

1.2.1. Comply with the rules of internal labor regulations;

1.2.2. Know and comply with the rules on labor protection when working at telephone enterprises in the scope of the duties performed, annually confirm the III electrical safety group;

1.2.3. Perform only the work that is defined in the operating instructions for the equipment or job descriptions approved by the administration of the enterprise, and provided that safe methods of doing it are well known;

1.2.4. Know and be able to provide first aid to victims of electric current and other accidents;

1.2.5. Follow the instructions on fire safety measures.

1.3. When servicing telegraph lines, the following hazardous and harmful production factors are possible:

  • dangerous voltage in the electrical circuit, the closure of which can occur through the human body, electric shock.
  • the occurrence of harmful substances (lead aerosols);
  • low air humidity and high temperature;
  • insufficient illumination of the working area;
  • fire hazard.

1.4. The victim or eyewitness immediately notifies the immediate supervisor of each accident at work.

1.5. The telecom operator is responsible for the preparation of the workplace, including, but not limited to, carrying out work without removing the voltage.

1.6. For non-compliance with this instruction, the perpetrators are held accountable in accordance with the internal labor regulations or penalties determined by the Labor Code of the Russian Federation.

2. Labor protection requirements before starting work

2.1. Put on and carefully tuck in the special clothing (robe) established in accordance with current standards, avoiding hanging ends and constraint when moving.

2.2. Check and verify the availability and serviceability of the fixed tool, devices to ensure the safe performance of work, fire extinguishing equipment.

2.3. Check the condition of general and ordinary lighting.

2.4. Do not carry out any work on the repair of fixtures, equipment, etc., if this is not part of the employee's responsibilities.

2.5. Report all shortcomings and malfunctions found during the inspection at the workplace to the shift supervisor for taking measures to eliminate them completely.

2.6. Place the tool in the workplace with maximum ease of use, avoiding the presence of unnecessary items in the work area.

2.7. Check the availability of a first aid kit.

3. Labor protection requirements during work

3.1. Work only in serviceable and carefully fitted overalls and safety shoes and use personal protective equipment required at the workplace in accordance with current standards.

3.2. Telegraph housings must be grounded.

3.3. The cords of the devices must be in rubber hoses.

3.4. When turning off the telegraph machine, grasp the plug of the power cord; it is forbidden to grasp the cord of the plug.

3.5. Replacing the roll tape and perforated tape should be done with the cord turned off.

3.6. Changing individual fuses should be done with only one hand, and the second or part of the body should not touch grounded structures

3.7. Enclosures and covers on equipment that cover 42 V AC contacts must display the electrical voltage symbol to alert service personnel to the danger of electrical shock.

3.8. Magnetic heads on electronic exchanges are cleaned with alcohol or compressed air from special cartridges.

3.9. Cleaning of telegraph equipment devices must be carried out with technical detergents based on surfactants and, as an exception, with gasoline. To wash parts of telegraph sets, liquid detergents such as "Impulse", "Vertolin-74" should be used.

3.10. It is forbidden to use leaded gasoline for cleaning telegraph devices.

3.11. Cases of telegraph devices, measuring instruments, step-down transformers for a voltage of 220 V must be grounded.

4. Labor protection requirements in emergency situations

4.4. Each employee who discovers violations of the requirements of this instruction and labor protection rules or notices a malfunction of the equipment that poses a danger to people is obliged to report this to the immediate supervisor.

In cases where a malfunction of the equipment poses a threatening danger to people or the equipment itself, the employee who discovered it is obliged to take measures to terminate the operation of the equipment, and then notify the immediate supervisor about this. Troubleshooting is carried out in compliance with safety requirements.

4.5. If an accident occurs during work, it is necessary to immediately provide first aid to the victim, report the incident to your immediate supervisor and take measures to preserve the situation of the accident, if this is not associated with a danger to life and health of people.

4.6. In case of electric shock, it is necessary to release the victim from the action of the current as soon as possible, in case of working at height, take measures to prevent him from falling. Switch off the equipment using switches, a plug-in connector, cut the supply wire with a tool with insulated handles. If it is impossible to turn off the equipment quickly enough, other measures must be taken to free the victim from the action of the current. To separate the victim from current-carrying parts or wires, use a stick, board or some other dry object that does not conduct electricity, while the caregiver must stand on a dry, non-conductive place, or wear dielectric gloves.

4.7. If a fire occurs in a technical room, you should immediately start extinguishing it with the available means (carbon dioxide fire extinguishers, asbestos blankets, sand) and call the fire department.

4.8. If extraneous voltage is detected at the workplace, it is necessary to immediately stop work and report to the shift supervisor.

4.9. In the event of a power failure while working with a power tool or a break in work, the power tool must be "Unplugged".

5. Labor protection requirements at the end of work

5.4. It is necessary to tidy up the workplace, tools and fixtures.

5.5. Inform the shifter (shift supervisor) of all malfunctions noticed during work and the measures taken to eliminate them

5.6. Overalls (robe and slippers) must be removed in a specially designated place.

5.7. Wash your face and hands thoroughly with warm water and soap, rinse your mouth well.

 We recommend interesting articles Section Standard instructions for labor protection:

▪ A mechanic-repairman of an automobile gas filling station (AGZS). Standard instruction on labor protection

▪ Handling oxygen and acetylene cylinders. Standard instruction on labor protection

▪ Machinist-clerk. Standard instruction on labor protection

See other articles Section Standard instructions for labor protection.

Read and write useful comments on this article.

<< Back

Latest news of science and technology, new electronics:

Artificial leather for touch emulation 15.04.2024

In a modern technology world where distance is becoming increasingly commonplace, maintaining connection and a sense of closeness is important. Recent developments in artificial skin by German scientists from Saarland University represent a new era in virtual interactions. German researchers from Saarland University have developed ultra-thin films that can transmit the sensation of touch over a distance. This cutting-edge technology provides new opportunities for virtual communication, especially for those who find themselves far from their loved ones. The ultra-thin films developed by the researchers, just 50 micrometers thick, can be integrated into textiles and worn like a second skin. These films act as sensors that recognize tactile signals from mom or dad, and as actuators that transmit these movements to the baby. Parents' touch to the fabric activates sensors that react to pressure and deform the ultra-thin film. This ... >>

Petgugu Global cat litter 15.04.2024

Taking care of pets can often be a challenge, especially when it comes to keeping your home clean. A new interesting solution from the Petgugu Global startup has been presented, which will make life easier for cat owners and help them keep their home perfectly clean and tidy. Startup Petgugu Global has unveiled a unique cat toilet that can automatically flush feces, keeping your home clean and fresh. This innovative device is equipped with various smart sensors that monitor your pet's toilet activity and activate to automatically clean after use. The device connects to the sewer system and ensures efficient waste removal without the need for intervention from the owner. Additionally, the toilet has a large flushable storage capacity, making it ideal for multi-cat households. The Petgugu cat litter bowl is designed for use with water-soluble litters and offers a range of additional ... >>

The attractiveness of caring men 14.04.2024

The stereotype that women prefer "bad boys" has long been widespread. However, recent research conducted by British scientists from Monash University offers a new perspective on this issue. They looked at how women responded to men's emotional responsibility and willingness to help others. The study's findings could change our understanding of what makes men attractive to women. A study conducted by scientists from Monash University leads to new findings about men's attractiveness to women. In the experiment, women were shown photographs of men with brief stories about their behavior in various situations, including their reaction to an encounter with a homeless person. Some of the men ignored the homeless man, while others helped him, such as buying him food. A study found that men who showed empathy and kindness were more attractive to women compared to men who showed empathy and kindness. ... >>

Random news from the Archive

Charging trailer for electric cars 17.02.2023

The American company Colorado Teardrops, by connecting a trailer with a battery, has thus made a unique paverbenko. This is also a full-fledged motor home, and if the user needs to reduce the time while the car is charging, then inside the camper all conditions for relaxation are created.

Inside the camper called The Boulder can accommodate up to 4 people. There is a 75 kWh battery with reverse charging when parked.

For an additional fee, you can equip the trailer with other devices - install an air conditioner, a heater, a water tank with a hand pump, etc.

The start of sales of such trailers is scheduled for the second half of 2023. The base price was set at $67, but there is a $12 rebate under the federal loan program.

Other interesting news:

▪ Action cameras GoPro Hero5 Black and Hero5 Session

▪ New low-cost processor delivers 1000x faster video

▪ Helioboat

▪ Greenland pops up

▪ Electric car Letin Mengo

News feed of science and technology, new electronics

 

Interesting materials of the Free Technical Library:

▪ Telephony site section. Article selection

▪ article Money for a barrel. Popular expression

▪ article What kind of person has a wild crocodile been friends with for 20 years? Detailed answer

▪ article The machinist of the plastering station is mobile. Standard instruction on labor protection

▪ article Lacquer for gilded baguettes. Simple recipes and tips

▪ article Soap bubbles on a stand. physical experiment

Leave your comment on this article:

Name:


Email (optional):


A comment:





All languages ​​of this page

Home page | Library | Articles | Website map | Site Reviews

www.diagram.com.ua

www.diagram.com.ua
2000-2024