Catalog and description of domestic electric meters. Reference data. SO-EE6706

SO-EE6706

Case round

Measurement and accounting of electric energy in single-phase AC networks

  • accuracy class: 2.0
  • rated-maximum current, A: 5-20; 10-40
  • rated frequency 50 Hz
  • apparent and active power consumed by the voltage circuit 5,5V.A and 1,3 W, respectively
  • total power consumed by the current circuit, not more than 0,35 V.A
  • operating temperature range, 0С: from -20 to +60
  • calibration interval: 16 years
  • average service life: at least 32 years
Catalog and description of domestic electric meters. Reference data. SO-EE6705

SO-EE6705. Single-phase induction electric energy meter

Rectangular housing

Measurement and accounting of electric energy in single-phase AC networks

  • accuracy class: 2.0
  • rated-maximum current, A: 5-20; 10-40
  • rated frequency 50 Hz
  • apparent and active power consumed by the voltage circuit 5,5V.A and 1,3 W, respectively
  • total power consumed by the current circuit, not more than 0,35 V.A
  • operating temperature range, 0С: from -20 to +60
  • calibration interval: 16 years
  • average service life: at least 32 years
Catalog and description of domestic electric meters. Reference data. CE2726

CE2726. Electrical energy meter electronic single-phase

Measurement and accounting of electric energy and power at 4 tariffs

  • accuracy class: 1.0
  • rated-maximum current, A: 5-50
  • rated frequency 50 Hz
  • apparent and active power consumed by the voltage circuit 5,0V.A and 2,0 W, respectively
  • total power consumed by the current circuit, not more than 0,5 V.A
  • operating temperature range, 0С: from -25 to +55
  • calibration interval: 16 years
  • average service life: at least 30 years
  • telemetry output
  • there is a modification with a built-in electric power modem
The counter provides commercial accounting in systems (ASKUE)

Catalog and description of domestic electric meters. Reference data. CE-2705

CE-2705
  • rated voltage of the monitored network 220 V
  • voltage variation range of the controlled network (187…242) V
  • rated load current 5 A
  • maximum load current 50 A
  • minimum load current 0,25 A
  • short-term overcurrent150 A
  • rated frequency of the controlled network50 Hz
  • frequency range of controlled network (47,5…52,5) ​​Hz
  • apparent power consumed by the current circuit, not more than 0,05 VA
  • active and apparent power consumed in the voltage circuit no more than 2,5 VA
  • accuracy class in the load range 1…1000% of nom. current1,0; 2,0
  • transmission ratio of the main transmission device16000 imp./kWh
  • calibration interval 16 years
  • average service life 30 years
Catalog and description of domestic electric meters. Reference data. SOLO

SOLO

Measurement and metering of electricity in the domestic, small-engine and industrial sectors

  • accuracy class: 1.0; 2.0
  • rated-maximum current, A: 5-60; 10-80; 10-100
  • rated frequency 50 Hz
  • apparent and active power consumed by the voltage circuit 8,0V.A and 2,0 W, respectively
  • total power consumed by the current circuit, not more than 0,5 V.A
  • operating temperature range, 0С: from -25 to +55
  • calibration interval: 16 years
  • average service life: at least 30 years
  • telemetry output
The counter provides commercial accounting in systems

Catalog and description of domestic electric meters. Reference data. Mercury-200

Mercury-200

AC active energy watt-hour meter static

Measurement and metering of electricity in the domestic, small-engine and industrial sectors

  • accuracy class: 2.0
  • rated-maximum current, A: 5-50
  • rated frequency 50 Hz
  • apparent and active power consumed by the voltage circuit 10V.A and 2,0 W, respectively
  • total power consumed by the current circuit, not more than 2,5 V.A
  • operating temperature range, 0С: from -20 to +55
  • calibration interval: 8 or 16 years (see modifications)
  • average service life: at least 30 years
  • number of tariff zones: 1-4
  • multi-tariff meters have a serial built-in CAN interface that provides information exchange with a computer
  • the possibility of mounting both in the traditional way and on a DIN rail.
Catalog and description of domestic electric meters. Reference data. SA4-I672M, SA4U-I672M

SA4-I672M, SA4U-I672M

Three-phase induction electric energy meter

Three-phase induction active energy meter for direct and transformer connection

Measurement and accounting of active energy in three-phase three- and four-wire AC networks

  • accuracy class: 2.0
  • rated frequency 50 Hz
  • total power consumed by the voltage circuit from 5,0 to 6,0 VA, active from 1,5 to 2,0 W (depending on the type of meter)
  • total power consumed by the current circuit from 0,6 to 1,0 V.A, and with a maximum current of more than 30A, not more than 2,5 V.A
  • operating temperature range, 0С: from 0 to +40
  • calibration interval: 6 years
  • average service life: at least 32 years
  • full product range for rated-maximum current, voltage and connection diagrams
Catalog and description of domestic electric meters. Reference data. SA4-I678, SA4U-I678

SA4-I678, SA4U-I678. Three-phase induction electric energy meter

Three phase induction

Active energy of direct and transformer connection

Measurement and accounting of active energy in three-phase three- and four-wire AC networks

  • accuracy class: 2.0
  • rated frequency 50 Hz
  • total power consumed by the voltage circuit from 5,0 to 6,0 VA, active from 1,5 to 2,0 W (depending on the type of meter)
  • total power consumed by the current circuit from 0,6 to 1,0 V.A, and with a maximum current of more than 30A, not more than 2,5 V.A
  • operating temperature range, 0С: from 0 to +40
  • calibration interval: 6 years
  • average service life: at least 32 years
  • full product range for rated-maximum current, voltage and connection diagrams
Catalog and description of domestic electric meters. Reference data. SA3-I670M, SA3U-I670M

SA3-I670M, SA3U-I670MS three-phase induction electric energy meter

Three phase induction

Active energy of direct and transformer connection

Measurement and accounting of active energy in three-phase three- and four-wire AC networks

  • accuracy class: 2.0
  • rated frequency 50 Hz
  • total power consumed by the voltage circuit from 5,0 to 6,0 VA, active from 1,5 to 2,0 W (depending on the type of meter)
  • total power consumed by the current circuit from 0,6 to 1,0 V.A, and with a maximum current of more than 30A, not more than 2,5 V.A
  • operating temperature range, 0С: from 0 to +40
  • calibration interval: 6 years
  • average service life: at least 32 years
  • full product range for rated-maximum current, voltage and connection diagrams
Catalog and description of domestic electric meters. Reference data. SR4-I673M, SR4U-I673M

SR4-I673M, SR4U-I673M. Three-phase induction electric energy meter

Reactive energy of direct and transformer connection

Measurement and accounting of reactive energy in three-phase three- and four-wire AC networks

  • accuracy class: 2.0 (for direct connection meters 3.0)
  • rated frequency 50 Hz
  • total power consumed by the voltage circuit from 5,0 to 6,0 VA, active from 1,5 to 2,0 W (depending on the type of meter)
  • total power consumed by the current circuit from 0,6 to 1,0 V.A, and with a maximum current of more than 30A, not more than 2,5 V.A
  • operating temperature range, 0С: from 0 to +40
  • calibration interval: 6 years
  • average service life: at least 32 years
  • full product range for rated-maximum current, voltage and connection diagrams
Catalog and description of domestic electric meters. Reference data CE2727

CE2727. Electrical energy meters three-phase electronic

Three-phase electronic active energy of direct and transformer connection

Measurement and accounting of active energy in three-phase three- and four-wire AC networks at 8 tariffs in 8 time zones

  • accuracy class: 1.0
  • rated voltage, V: 3 x 57,7; 3 x 100; 3 x 380; 3 x 220/380
  • rated-maximum current, A: 1-2; 5-10; 5-50; 10-100
  • rated frequency 50 Hz
  • apparent and active power consumed by the voltage circuit 5,0V.A and 2,0 W, respectively
  • total power consumed by the current circuit, not more than 0,2 V.A
  • operating temperature range, 0С: from -25 to +55
  • calibration interval 8 years
  • average service life of at least 30 years
  • interface: RS232; RS485; telemetry channel
  • calibration interval 8 years
The presence of a modification with a built-in electric power modem allows the use of a meter in the system (ASKUE) with data transmission over a power network of 0,4 kV

Catalog and description of domestic electric meters. Reference data. F669

F669. Electric energy meter three-phase electronic

Three-phase multifunctional active-reactive

Measurement of active and reactive energy and power in two directions at 4 tariffs in 5 time zones

  • accuracy class: 0.5S; 1.0
  • rated voltage depending on the connection diagram
  • rated-maximum current, A: 1-1,25; 5-6,25
  • rated frequency 50 Hz
  • apparent and active power consumed by the voltage circuit 4,0V.A and 2,0 W, respectively
  • total power consumed by the current circuit, not more than 0,3 V.A
  • operating temperature range, 0С: from -20 to +55
  • calibration interval 8 years
  • average service life of at least 20 years
  • interfaces: "current loop" type, telemetry output, optoport, RS232; RS485
The counter in terms of its functionality is not inferior to the best foreign samples

Catalog and description of domestic electric meters. Reference data. Mercury 230

Mercury 230. Electric energy meter three-phase electronic

Three-phase electronic multifunction active and active-reactive energy

Measurement and accounting of active and active-reactive energy in the forward direction in three-phase AC networks with a nominal frequency of 50 Hz.

  • active energy accuracy class: 0,5; 1,0
    active-reactive energy: 0,5(1,0); 1,0(2,0)
  • rated-maximum current, A; 5-50; 10-100; 5-7,5
  • total and active power consumed by the voltage circuit 7,5V.A and 0,5W, respectively
  • total power consumed by the current circuit 0,1V.A
  • number of tariff zones: 1- 4
  • operating temperature range C: from -20 to +55
  • calibration interval - 8 years
  • average service life of at least 30 years
  • counters have a serial CAN interface that provides information exchange with a computer
  • counters can be used both autonomously and in ASKUE systems
Catalog and description of domestic electric meters. Reference data. SO-50

SO-505. Single-phase electricity meter

Designed to account for active electricity in everyday life, public and industrial premises. The principle of operation of the SO-505 electric meter is based on the use of an induction measuring system. The SO-505 electric meter has a version of SO-505T with a telemetric output. The reading telemetry device allows using the meter in an automated system for monitoring and accounting for electricity.

Options for the casing, the presence of a backstop are determined by the customer.

Catalog and description of domestic electric meters. Reference data. ESR-5

ESR-5. Single-phase electric meter

SOE-5 electric meters are designed to measure active electrical energy in two-wire alternating current circuits with a voltage of 220V, a frequency of 50Hz. They are available in three versions: single-tariff, two-tariff with an external tariff switch and multi-tariff with an internal tariff for work in automated systems for monitoring and accounting for energy consumption. Counters with an internal rater have a digital RS-232 or RS-485 interface. With the help of a digital interface, the tariffs are set, the clock accuracy is adjusted, and data is read. The meters are provided with non-volatile EEPROM memory for storing information. The memory registers store data for each tariff. The meters have a telemetric output galvanically isolated from other circuits.

Catalog and description of domestic electric meters. Reference data. ESR-52

ESR-52. Single-phase electric meter

SOE-52 electric meters are designed to account for electricity consumption in two-wire electric current circuits in enclosed spaces. They can be operated autonomously and as part of an automated control system and electricity metering (ASKUE) using a pulse output. Meters comply with GOST 30207-94 (IEC 1036-90) and are registered in the State Register of Measuring Instruments No. 17301-02. - Use of SMD mounting - Presence of a telemetric output

Catalog and description of domestic electric meters. Reference data. SA4U-510, SA4-514, SA4-518

СА4У-510, СА4-514, СА4-518. Three-phase induction meter

Designed to account for active electricity in three-phase four-wire AC networks at industrial enterprises and household consumers. Execution options: СА4У-510Т, СА4-514Т, СА4-518Т have a built-in photoelectronic adapter with a telemetric output for operation in automated systems for monitoring and accounting for energy consumption. At the request of the customer, a backstop is installed on the meters to prevent theft of electricity. Electric meters are made of non-combustible materials.

TECH SPECS: SA4U-510 SA4-514 SA4-518
Accuracy class 2,0 2,0 2,0
Switching method transformer straight straight
Rated voltage, V 3х220 / 380 3х220 / 380 3х220 / 380
Network frequency, Hz 50 50 50
Rated current, A 3x5 3x10 3x20 (3x10)
Maximum current, A 3x6,25 3x40 3x80
Maximum current, %I rated 125 400 400 (800)
Sensitivity threshold, A 0,025 0,05 0,1 (0,05)
Gear ratio, rev/kWh 600 125 60
Number of telemetry output pulses, for version "T" imp/kWh 600 125 60

Catalog and description of domestic electric meters. Reference data. TE560

TE560/ Three-phase microprocessor-based electricity meter

Electric meters of the STE560 series are designed to account for active and reactive electric energy in three- and four-wire networks of three-phase alternating current at industrial enterprises and household consumers, as well as for operation as part of automated systems for monitoring and accounting for energy consumption. The counters are built on a DSP digital signal processor and are regulated using special programs. Non-volatile EEPROM memory is provided for storing information in meters. The memory registers store data for each tariff. The meters have a telemetry output, galvanically isolated from other circuits. To display information, a liquid crystal indicator is used, which works stably at low temperatures. The meters have a digital interface IRPS (current loop). With the help of a digital interface, adjustment is made, setting the time of the tariffs, adjusting the hours and, if necessary, reading the meter readings using a computer.

TECH SPECS:
Accuracy class:
- active energy 1,0
- for reactive energy 2,0
Rated voltage, V 3х220/380; 3х57,7/100; 3х100
Rated current, A 5; 10
Maximum current, A 7,5; 40; 80
Sensitivity:
- active energy, % Inom 0,25
- by reactive energy, % Inom 0,4
Meter constant, imp/kWh 1000, 5000
Working temperature, оС from -20 to + 55
Average service life, years 30
MTBF, h 100000
Check interval, years 10
Overall dimensions, mm 317 (283) x174x75
Weight, not more than kg 1,65

Catalog and description of domestic electric meters. Reference data. STS5605, STS5602

STS5605, STS5602

Three-phase microprocessor-based combined meterSTS5605, STS5602 series meters are three-phase, multi-tariff, electronic, digital, combined devices that combine a multifunctional microprocessor meter and a power quality indicator meter. Meters of the STS5605 series of transformer connection are designed to measure active and reactive electricity at industrial enterprises and energy facilities. Used in systems ASKUE to transfer the measured values ​​to the control room for control, accounting and distribution of electrical energy.

Catalog and description of domestic electric meters. Reference data. STK-3 Catalog and description of domestic electric meters. Reference data Catalog and description of domestic electric meters. Reference data

STK-3 Single and three-phase electric meterDesigned to measure active and reactive energy in single- and three-phase circuits of three- and four-wire alternating current circuits, with the possibility of accounting in two directions, with direct or transformer connection, autonomously or as part of automated control systems and electricity metering (ASKUE). energy at energy facilities, at industrial enterprises, in the public sector in the context of the use of time-differentiated tariffs for electrical energy. Counters can be used in ASKUE for technical or commercial accounting.

Measuring network frequency, Hz 50
Sensitivity threshold, mA from 4
Total power consumption of the parallel circuit, VA to 3,6
Total power consumption of the serial circuit, VA to 0,3
Gear ratio of pulse telemetry output, imp/kvar h from 1000 to 100000
Number of telemetry outputs 1,2,4
Weight, no more than, kg 2,8
Load chart for each quadrant, number of metering points 2160
Digital interface RS 485
Self-diagnosis system Yes
Overall dimensions, "Energy 8", "STK3-"mm 330h170h70
Overall dimensions, STK1-10 200h130h80
Integration period 1,3,5,10,30,60
Number of seasons to 12
Number of time zones for each season 6
Rated voltage U, V 57,7, 100, 220, 380
Rated (maximum) current, A 1(1,5), 5(7,5),
10 (40), 40 (100)
Number of switched outputs up to 4's
RS 485 baud rate up to 19200 baud
Check interval 6 years
Relative humidity at 30°C up to 90%
Atmosphere pressure 70 to 106,7 kPa

Catalog and description of domestic electric meters. Reference data. A100

A100 The A100 meter is designed to account for active energy in single-phase AC circuits in the single- and multi-tariff mode, as well as for use as part of automated control systems and electricity metering (ASKUE). The A100 counter is distinguished by workmanship, resistance to temperature changes, a high level of information security, insensitivity to the constant component and small dimensions.Functionality

  • Counter A100 allows:
  • Carry out both one- and two-tariff electricity metering. Tariff switching is carried out from an external tariff setter.
  • Register and store in memory data confirming the accuracy of information, such as:
    • Total active energy in the opposite direction.
    • Direct indication of the energy flow in the opposite direction on the LCD.
    • Number of power outages.
    • The total running time of the counter.
    • Operating time since the last power-up.
    • The time spent by the meter in the absence of current.
    • The number of restarts of the microprocessor.
    • Number of cases of active energy reversal.
  • Transmit data via infrared (IrDA) or pulse output (RJ11).
  • Store data when power is off in non-volatile EEPROM memory.
Catalog and description of domestic electric meters. Reference data. A1000

A1000

A1000 meters are designed to account for active, reactive energy and measure power in one or two directions in three-phase AC circuits, both in one and in multi-tariff mode.

Functionality

Counter A1000 allows:

  • Carry out both one and multi-tariff electricity metering (up to 4 tariffs). Tariff switching is carried out from an external tariff setter.
  • Perform 2 measurements in multi-tariff mode:
    • +P - active consumed energy;
    • +P, -P - active consumed and delivered energy;
    • +P, +Q - active and reactive consumed energy;
    • +Q, -Q - reactive consumed and issued energy;
    • P = |P1|+ |P2|+ |P3| - active energy modulo;
    • P = |P1|+ |P2|+ |P3|, +Q - modulo active and reactive consumed energy;
  • Fix maximum power.
  • Register energy when the specified load power threshold is exceeded.
  • Register the absence of voltage in one or two phases.
  • Measure and display phase-by-phase voltages, currents, active, reactive and apparent power of the network.
Catalog and description of domestic electric meters. Reference data. ALFA Plus (A2)

ALFA Plus (A2)

Multifunctional microprocessor-based three-phase electricity meters ALPHA Plus (A2) is designed to account for active and reactive energy and power in 3-phase AC circuits, control power quality parameters, and also for operation as part of ASKUE.

Functionality

  • Measurement of active and reactive energies and powers in two directions.
  • Accounting for consumed and supplied energy in multi-tariff mode.
  • Measurement of the maximum load power at the calculated time interval, fixing the date and time of the maximum active and reactive power for each tariff zone.
  • Recording and storage in the memory of the load graph data counter.
  • Automatic load control with the possibility of its shutdown or signaling.
  • Transfer of measurement results via digital and pulse communication interfaces (up to two groups of galvanically isolated relays).
Electricity parameters

The ALPHA Plus counter measures, calculates and displays up to 46 values ​​related to electricity parameters. These include:

  • Phase currents and voltages.
  • Active, reactive and apparent power of the network.
  • Active, reactive and apparent power of the phases.
  • Power factor cos of the network and each phase.
  • Phase angles of voltage and current vectors.
  • Second harmonic value by voltage phases.
  • Second harmonic value by current phases.
  • The distortion factor of the sinusoidal voltage and current.
  • network frequency.
Catalog and description of domestic electric meters. Reference data. Delta

Delta

The Delta meter is designed to account for active or active-reactive energy in three- and single-phase AC circuits, both in single- and multi-tariff mode, as well as for use as part of automated control systems and electricity metering (ASKUE).

  • Measurement of active or active-reactive energy.
  • Both single and multi-tariff electricity metering.
  • DIN rail or panel mounting.
  • Pulse outputs for work in ASKUE.
Catalog and description of domestic electric meters. Reference data. ST-ER01 (SET)

ST-ER01 (SET)

  • accuracy class: 1.5
  • rated-maximum current, A: 5; 7.5
  • rated frequency 50 Hz
  • Voltage 3x57.7/100
  • total power consumed by the voltage circuit 1V.A
  • operating temperature range, 0С: from -25 to +55
  • calibration interval: 6 years
ST-ER02 (SET)
  • accuracy class: 1.5
  • rated-maximum current, A: 5; 50
  • rated frequency 50 Hz
  • Voltage 3x380/220
  • total power consumed by the voltage circuit 4.5V.A
  • operating temperature range, 0С: from -25 to +55
  • calibration interval: 6 years
ST-EA03 (SET)
  • accuracy class: 1
  • rated-maximum current, A: 5; 7.5
  • rated frequency 50 Hz
  • Voltage 3x100
  • total power consumed by the voltage circuit 1V.A
  • operating temperature range, 0С: from -10 to +55
  • calibration interval: 6 years
ST-EA05 (SET)
  • accuracy class: 1
  • rated-maximum current, A: 5; 7.5
  • rated frequency 50 Hz
  • Voltage 3x100
  • total power consumed by the voltage circuit 1V.A
  • operating temperature range, 0С: from -10 to +55
  • calibration interval: 6 years
Catalog and description of domestic electric meters. Reference data. SO-EA05

SO-EA05

  • accuracy class: 1.0
  • rated-maximum current, A: 10; 50
  • rated frequency 50 Hz
  • apparent and active power consumed by the voltage circuit 5,5V.A and 1,3 W, respectively
  • operating temperature range, 0С: from -35 to +55
  • calibration interval: 6 years
Publication: pozitron.ru

See other articles Section Reference materials.

Read and write useful comments on this article.

<< Back

Latest news of science and technology, new electronics:

Traffic noise delays the growth of chicks 06.05.2024

The sounds that surround us in modern cities are becoming increasingly piercing. However, few people think about how this noise affects the animal world, especially such delicate creatures as chicks that have not yet hatched from their eggs. Recent research is shedding light on this issue, indicating serious consequences for their development and survival. Scientists have found that exposure of zebra diamondback chicks to traffic noise can cause serious disruption to their development. Experiments have shown that noise pollution can significantly delay their hatching, and those chicks that do emerge face a number of health-promoting problems. The researchers also found that the negative effects of noise pollution extend into the adult birds. Reduced chances of reproduction and decreased fertility indicate the long-term effects that traffic noise has on wildlife. The study results highlight the need ... >>

Wireless speaker Samsung Music Frame HW-LS60D 06.05.2024

In the world of modern audio technology, manufacturers strive not only for impeccable sound quality, but also for combining functionality with aesthetics. One of the latest innovative steps in this direction is the new Samsung Music Frame HW-LS60D wireless speaker system, presented at the 2024 World of Samsung event. The Samsung HW-LS60D is more than just a speaker system, it's the art of frame-style sound. The combination of a 6-speaker system with Dolby Atmos support and a stylish photo frame design makes this product the perfect addition to any interior. The new Samsung Music Frame features advanced technologies including Adaptive Audio that delivers clear dialogue at any volume level, and automatic room optimization for rich audio reproduction. With support for Spotify, Tidal Hi-Fi and Bluetooth 5.2 connections, as well as smart assistant integration, this speaker is ready to satisfy your ... >>

A New Way to Control and Manipulate Optical Signals 05.05.2024

The modern world of science and technology is developing rapidly, and every day new methods and technologies appear that open up new prospects for us in various fields. One such innovation is the development by German scientists of a new way to control optical signals, which could lead to significant progress in the field of photonics. Recent research has allowed German scientists to create a tunable waveplate inside a fused silica waveguide. This method, based on the use of a liquid crystal layer, allows one to effectively change the polarization of light passing through a waveguide. This technological breakthrough opens up new prospects for the development of compact and efficient photonic devices capable of processing large volumes of data. The electro-optical control of polarization provided by the new method could provide the basis for a new class of integrated photonic devices. This opens up great opportunities for ... >>

Random news from the Archive

The latest solar panels for spacecraft 07.11.2012

ATK has been awarded a $6,4 million contract to further develop Megaflex solar panels that can generate 10 times more power than today's largest satellite solar panels. This is not only a very important component for future "traditional" chemical-fueled spacecraft, but also the main part of NASA's promising spacecraft for electric propulsion (Solar Electrical Propulsion spacecraft).

MegaFlex solar panels are specifically designed to meet the expected high energy demand of 350 kW and above. At the same time, the new panels will have to have a very low weight and a small volume when folded. MegaFlex technologies are based on the very successful and proven UltraFlex panels that powered NASA's Mars Phoenix Lander, for example. They are in serial production and will be used on many promising devices. In particular, light and compact UltraFlex panels are installed on the Orion spacecraft, which, with a diameter of only 6 m, produce a power of 15 kW.

In accordance with the contract, within 18 months, ATK specialists must double the size of the array of solar panels developed for the Orion spacecraft. This will increase the level of technical readiness of the MegaFlex project, develop the necessary controls and prepare the panels for the first demonstration space flight.

Other interesting news:

▪ TV SONY KDP57WS550 with a diagonal of 57 inches

▪ apple ipad

▪ A new way to control smart watches

▪ Picasa will be updated

▪ Ink changes color

News feed of science and technology, new electronics

 

Interesting materials of the Free Technical Library:

▪ section of the site Sites of amateur radio equipment. Article selection

▪ article by Dale Breckenridge Carnegie. Famous aphorisms

▪ article Is the area of ​​ice caps shrinking at the poles? Detailed answer

▪ article Length units. Travel Tips

▪ article Digital capacitance meter. Encyclopedia of radio electronics and electrical engineering

▪ article LED as an indicator of mains voltage. Encyclopedia of radio electronics and electrical engineering

Leave your comment on this article:

Name:


Email (optional):


A comment:





All languages ​​of this page

Home page | Library | Articles | Website map | Site Reviews

www.diagram.com.ua

www.diagram.com.ua
2000-2024