ENCYCLOPEDIA OF RADIO ELECTRONICS AND ELECTRICAL ENGINEERING
Section 2. Sewerage of electricity Overhead power lines with voltage up to 1 kV. Grounding. Surge protection Encyclopedia of radio electronics and electrical engineering / Rules for the installation of electrical installations (PUE) 2.4.38. Grounding devices designed for re-grounding, protection against lightning surges, grounding of electrical equipment installed on overhead line supports must be made on the overhead line supports. The resistance of the grounding device must be no more than 30 ohms. 2.4.39. Metal supports, metal structures and reinforcement of reinforced concrete support elements must be connected to the PEN conductor. 2.4.40. On reinforced concrete poles, the PEN conductor should be connected to the reinforcement of reinforced concrete pillars and struts of the poles. 2.4.41. Hooks and pins of wooden poles of overhead lines, as well as metal and reinforced concrete poles when suspended on them with an insulated carrier conductor or with all carrier conductors of the bundle, are not subject to grounding, with the exception of hooks and pins on the poles, where repeated grounding and grounding are performed to protect against atmospheric overvoltages. 2.4.42. Hooks, pins and fittings of overhead lines with a voltage of up to 1 kV, limiting the crossing span, as well as supports on which joint suspension is carried out, must be grounded. 2.4.43. On wooden poles of the overhead line, when passing to the cable line, the grounding conductor must be connected to the PEN conductor of the overhead line and to the metal sheath of the cable. 2.4.44. Protective devices installed on overhead lines for protection against lightning surges must be connected to the grounding conductor with a separate descent. 2.4.45. The connection of the grounding conductors to each other, their connection to the upper grounding outlets of the racks of reinforced concrete supports, to hooks and brackets, as well as to grounded metal structures and to grounded electrical equipment installed on overhead line supports, must be carried out by welding or bolted connections. The connection of grounding conductors (descents) to the grounding conductor in the ground must also be carried out by welding or have bolted connections. 2.4.46. In a populated area with one- and two-story buildings, overhead lines must have grounding devices designed to protect against atmospheric surges. The resistance of these grounding devices should be no more than 30 ohms, and the distances between them should be no more than 200 m for areas with up to 40 thunderstorm hours per year, 100 m for areas with more than 40 thunderstorm hours per year. In addition, grounding devices must be made: 1) on supports with branches to the entrances to buildings in which a large number of people can be concentrated (schools, nurseries, hospitals) or which are of great material value (livestock and poultry premises, warehouses); 2) on the end supports of lines having branches to the inputs, while the greatest distance from the adjacent grounding of these same lines should be no more than 100 m for areas with a number of thunderstorm hours per year up to 40 and 50 m - for areas with a number of thunderstorm hours per year over 40. 2.4.47. At the beginning and end of each VLI line, it is recommended to install clamps on the wires for connecting voltage control devices and portable grounding. Grounding lightning surge protection devices are recommended to be combined with the re-grounding of the PEN conductor. 2.4.48. Requirements for grounding devices for re-grounding and protective conductors are given in 1.7.102, 1.7.103, 1.7.126. As grounding conductors on overhead line supports, it is allowed to use round steel with an anti-corrosion coating with a diameter of at least 6 mm. 2.4.49. Guys of overhead lines must be connected to the ground conductor. See other articles Section Rules for the installation of electrical installations (PUE). Read and write useful comments on this article. Latest news of science and technology, new electronics: Machine for thinning flowers in gardens
02.05.2024 Advanced Infrared Microscope
02.05.2024 Air trap for insects
01.05.2024
Other interesting news: ▪ Popcorn packaging for fragile items ▪ Nanosheets instead of platinum ▪ Concentration of thoughts hinders creativity ▪ Alarm signal - in every house News feed of science and technology, new electronics
Interesting materials of the Free Technical Library: ▪ section of the site Car. Article selection ▪ article Stone processing. History of invention and production ▪ article Which Asian state became independent against its will? Detailed answer ▪ article Logical elements and their electrical analogues. Radio - for beginners ▪ article Generator for measuring bridge. Encyclopedia of radio electronics and electrical engineering ▪ Article Hand snake. Focus Secret
Leave your comment on this article: All languages of this page Home page | Library | Articles | Website map | Site Reviews www.diagram.com.ua |