Menu English Ukrainian russian Home

Free technical library for hobbyists and professionals Free technical library


ENCYCLOPEDIA OF RADIO ELECTRONICS AND ELECTRICAL ENGINEERING
Free library / Schemes of radio-electronic and electrical devices

Electrostimulator of biologically active points. Encyclopedia of radio electronics and electrical engineering

Free technical library

Encyclopedia of radio electronics and electrical engineering / Electronics in medicine

Comments on the article Comments on the article

The electrical stimulator is designed to control and normalize body functions by exposing biologically active areas of the skin to a special form of weak electric current with the control of these points during exposure.

The electrostimulator is used for prevention and treatment at home, after consultation with a doctor and in compliance with all his recommendations.

The electrostimulator is powered by a "Korund" battery or a 7D-0,115-U1,1 battery.

The electrostimulator consists of a generator on the elements DD1.1 and DD1.2, a sound emitter HA1 and a light indicator VD5. The impact on active points is carried out with the help of remote electrodes included in the diagonal of the diode bridge VD1 ... VD4.

Electrostimulator of biologically active points

It is known that the resistance of those areas of the skin, where the active points are close to the surface, is small compared to other areas. This effect is used in the operation of the electrostimulator. In the initial state (with the power on), the generator assembled on the elements DD1.1 and DD1.2 does not work, but if a finite resistance appears between the electrodes, the generator starts to generate pulses. Indicators HA1, VD5 note this. The frequency of the generated oscillations is the higher, the lower the resistance between the electrodes. Therefore, the procedure for finding biologically active sites is reduced to finding a point on the skin when the emitter HA1 emits the highest sound.

The diode bridge VD1...VD4 is necessary in order to generate impact pulses of a certain polarity. Experts recommend acting on active points, as a rule, with a "negative" electrode. In this case, the "positive" electrode is considered common and can be located in the arm or in a place indicated by the doctor. Your doctor may recommend other options.

Chip K561LA9 can be replaced by K176LA9. Diodes KD522B are replaced by any of the series KD520, KD521. LED AL307B may be with a different letter. Emitter HA1 is replaced by ZP1; ZP2; ZP4; ZP5.

Author: M.Chupuksaev, Sverdlovsk region, Kachkanar; Publication: N. Bolshakov, rf.atnn.ru

See other articles Section Electronics in medicine.

Read and write useful comments on this article.

<< Back

Latest news of science and technology, new electronics:

Machine for thinning flowers in gardens 02.05.2024

In modern agriculture, technological progress is developing aimed at increasing the efficiency of plant care processes. The innovative Florix flower thinning machine was presented in Italy, designed to optimize the harvesting stage. This tool is equipped with mobile arms, allowing it to be easily adapted to the needs of the garden. The operator can adjust the speed of the thin wires by controlling them from the tractor cab using a joystick. This approach significantly increases the efficiency of the flower thinning process, providing the possibility of individual adjustment to the specific conditions of the garden, as well as the variety and type of fruit grown in it. After testing the Florix machine for two years on various types of fruit, the results were very encouraging. Farmers such as Filiberto Montanari, who has used a Florix machine for several years, have reported a significant reduction in the time and labor required to thin flowers. ... >>

Advanced Infrared Microscope 02.05.2024

Microscopes play an important role in scientific research, allowing scientists to delve into structures and processes invisible to the eye. However, various microscopy methods have their limitations, and among them was the limitation of resolution when using the infrared range. But the latest achievements of Japanese researchers from the University of Tokyo open up new prospects for studying the microworld. Scientists from the University of Tokyo have unveiled a new microscope that will revolutionize the capabilities of infrared microscopy. This advanced instrument allows you to see the internal structures of living bacteria with amazing clarity on the nanometer scale. Typically, mid-infrared microscopes are limited by low resolution, but the latest development from Japanese researchers overcomes these limitations. According to scientists, the developed microscope allows creating images with a resolution of up to 120 nanometers, which is 30 times higher than the resolution of traditional microscopes. ... >>

Air trap for insects 01.05.2024

Agriculture is one of the key sectors of the economy, and pest control is an integral part of this process. A team of scientists from the Indian Council of Agricultural Research-Central Potato Research Institute (ICAR-CPRI), Shimla, has come up with an innovative solution to this problem - a wind-powered insect air trap. This device addresses the shortcomings of traditional pest control methods by providing real-time insect population data. The trap is powered entirely by wind energy, making it an environmentally friendly solution that requires no power. Its unique design allows monitoring of both harmful and beneficial insects, providing a complete overview of the population in any agricultural area. “By assessing target pests at the right time, we can take necessary measures to control both pests and diseases,” says Kapil ... >>

Random news from the Archive

NXP Solar Mobile Phone Solution 27.11.2007

Hi-Tech Wealth (HTW) has selected the Nexperia Cellular System Solution 5110 from NXP Semiconductors for use in the world's first solar-powered mobile phone, the S116.

Designed by Laucent Technology, NXP's system solution delivers exceptionally low power consumption to optimize the solar charging process. As a result, the S116, which went into mass production in July this year, has achieved industry-leading standby and talk times.

The new solar-powered phone allows users to recharge the battery using any light source, even candlelight. This guarantees a longer standby time than any other phone on the market.

The combination of the functionality built into the Laucent design solution and the NXP Nexperia Cellular System Solution 5110 provides the SI 16 also with a wide range of multimedia applications and connectivity with minimal power consumption.

Other interesting news:

▪ Named the most attractive type of woman

▪ Rocket for flights to Mars and flights on Earth

▪ Fabric to keep you cool in the heat

▪ Nature improves heart rate

▪ Adsorbent instead of cold

News feed of science and technology, new electronics

Interesting materials of the Free Technical Library:

▪ section of the site Application of microcircuits. Article selection

▪ article Industrial ventilation and air conditioning. Basics of safe life

▪ article What are the Paralympic Games? Detailed answer

▪ Article Selection and replacement of incandescent electric lamps. Directory

▪ article Installation of grounding conductors. Encyclopedia of radio electronics and electrical engineering

▪ article Invulnerable water bag. Focus Secret

Leave your comment on this article:

Name:


Email (optional):


A comment:





All languages ​​of this page

Home page | Library | Articles | Website map | Site Reviews

www.diagram.com.ua

www.diagram.com.ua
2000-2024